Jual Laboratory HACH DR3900

 

Simplicity throughout: The DR3900 Spectrophotometer provides the simplest way to perform tests for water analysis. Used together with TNTplus™ test kits testing steps are reduced. The potential for human errors is minimized. The system of Spectrophotometer and test kits supports the process optimization of waste water treatment plants and environmental testing.This instrument connects to Claros, Hach’s innovative Water Intelligence System, enabling you to seamlessly connect and manage instruments, data, and process – anywhere, anytime. The result is greater confidence in your data and improved efficiency in your operations. To unlock the full potential of Claros, insist on Claros Enabled instruments.

Berikut ini tautan / link product dari HACH Spectrophotometer Series :

Jual Laboratory HACH DR3900

 

Simple Preparation

TNTplus vials use DosiCaps that are easier to use than Powder Pillows or Liquid Reagents, without any risk of contamination.

The boxes and vials are color-coded for fast and easy parameter and range recognition of exactly the test you need.

Step-by-step illustrated test methods are printed on the box as quick reference or can be called up in the instrument menu.

Fast execution

A 2D barcode on the TNTplus vial is automatically read by the Hach DR spectrophotometer to identify the appropriate method and take the measurement. The vial spins to take 10-fold absorbance readings that will be averaged for result determination to exclude scratches and fingerprints. Instrument calibration verification and high instrument stability all combine to eliminate the need to run reagent blanks.

Comprehensive Documentation

Measurement results are documented on the detailed level with timestamp, operator ID, absorbance reading, and calculated concentration. The 2D barcode delivers the lot number and expiry date, logged with every result.

*RFID technology currently available in the US, Puerto Rico, Austrailia, New Zealand, and Colombia only.

Customisable

With the ability to store hundreds of user-determined methods, operators are able to tailor the DR3900 to meet the everyday needs of the plant.

Being able to optimise and customise the method portfolio, combined with regular software updates and Claros connectivity, makes the DR3900 the ultimate solution to water quality lab needs.

 

Jual Laboratory HACH DR3900

HACH DR 3900 SPECTROPHOTOMETER

Specification

Beam Height

10 mm

Data Logger

2000 measured values
(Result, Date, Time, Sample ID, User ID)

Display

7″ TFT

Display Resolution

WVGA (800 pix x 480 pix)

Display Size

7 inch (17.8 cm)

Display Type

Colored touch-screen

Enclosure Rating

IP30

Includes

Adapter A for 1 in. round and 1 cm square cells, matched pair of 1 in. square glass sample cells, light shield,dust cover, printed basic user manual and benchtop power supply with 115 and 230V power cords.

Interfaces

USB type A (2)  ;  USB type B  ;  Ethernet  ;  RFID sensor

Manual Languages

English,French (CDN),Spanish (SA),Portuguese (BR), Chinese, Japanese,Korean

Max. Operating

Humidity

80 %

Max. Storage

Humidity

80 %

Operating

Conditions

10 – 40 °C

Operating

Mode

Transmittance (%),
Absorbance and Concentration,
Scanning

Optical System

Reference beam, spectral

Photometric Accuracy

5 mAbs @ 0.0 – 0.5 Abs

Photometric Accuracy 2

1 % at 0.50 – 2.0 Abs

Photometric
Linearity

< 0.5% – 2 Abs ; 2 Abs with neutral glass at 546 nm

Photometric
Measuring Range

± 3.0 Abs (wavelength range 340 – 900 nm)

Power Requirements

With external power supply

Power
Requirements (Hz)

50 / 60 Hz

Power Requirements
(Voltage)

110 – 240 V AC

Power Supply

Benchtop Power Supply

Preprogrammed

Methods

> 240

Region:US

Region:US

Sample Cell

Compatibility

Rectangular : 10 mm, 50 mm, 1 inch;

round: 13 mm, 16 mm, 1 inch

Source Lamp

Gas-filled Tungsten (visible)

Specific Technology

RFID not applicable with this model

Spectral Bandwidth

5 nm ± 1 nm

Standard Accessories

None

Storage Conditions

-30 – 60 °C

Stray Light

< 0.1% T at 340 nm with NaNO2

User Interface

Languages

Bulgarian, Chinese, Croatian, Czech, Danish,Dutch,English, Finnish, French, German, Greek, Hungarian,Italian, Japanese, Korean,Polish, Portuguese – Brazil,Portuguese, Russian, Serbian, Slovakian, Slowenian,
Spanish, Swedish, Turkish

User Programs

100

Warranty

12 months

Wavelength Accuracy

± 1.5 nm (wavelength range 340 – 900 nm)

Wavelength Calibration

Automatic

Wavelength Range

320 – 1100 nm

Wavelength Reproducibility

± 0.1 nm

Wavelength Resolution

1 nm

Wavelength Selection

Automatic

Weight

4.2 kg

Berikut ini tautan / link product dari HACH Spectrophotometer Series :

 

Available Tests

The following table lists available tests and overall ranges for the Hach DR 3900 Benchtop Spectrophotometer. The ranges may represent more than one available test for the instrument. Consult your Hach representative, Customer Service, the Hach Master Catalog, or the Hach web site at www.hach.com for complete details of all available tests for this instrument.

Parameter

Range

TNTplus

Range Test Parameter

Range

Alachlor

0.1 to 0.5 ppb,

Lead

3 µg/L to 2.0 mg/L

Alkalinity, Total

25 to 400 mg/L

Manganese

0.006 to 20.0 mg/L

Aluminum

0.002 to 0.800 mg/L

Mercury

0.1 to 2.5 µg/L

Ammonia, Nitrogen

0.015 to 50.0 mg/L

Methylethylketoxime

(MEKO)

15 to 1000 µg/L

Arsenic

0.020 to 0.200 mg/L

Molybdenum, Molybdate

0.02 to 40.0 mg/L

Atrazine

0.5 to 3.0 ppb,

Nickel

0.006 to 6.0 mg/L

Barium

2 to 100 mg/L

Nitrate, Nitrogen

0.01 to 35 mg/L

Benzotriazole

1.0 to 16.0 mg/L

Nitrite, Nitrogen

0.002 to 250 mg/L

Boron

0.2 to 14.0 mg/L

Nitrogen,

Simplified Total Kjeldahl

0 to 16 mg/L

Bromine

0.05 to 4.50 mg/L

Nitrogen, Total

0.5 to 150 mg/L

Cadmium

.7 µg/L to 0.30 mg/L

Nitrogen, Total Inorganic

0.2 to 25.0 mg/L

Carbohydrazide

5 to 600 µg/L

Nitrogen, Total Kjeldahl

1 to 150 mg/L

Chloramine, Mono

0.04 to 10.0 mg/L

Ozone

0.01 to 1.50 mg/L

Chloride

0.1 to 25.0 mg/L

PCB

(Polychlorinated Biphenyls)

1 to 50 ppm,

threshold

Chlorine Dioxide

0.01 to 1000 mg/L

Phenols

0.002 to 0.200 mg/L

Chlorine, Free

0.02 to 10.0 mg/L

Phosphonates

0.02 to 125.0 mg/L

Chlorine, Total

2 µg/L to 10.0 mg/L

Phosphorus,

Acid Hydrolyzable

0.06 to 100.0 mg/L

Chromium, Hexavalent

0.010 to 1.00 mg/L

Phosphorus,

Reactive (Orthophosphate)

19 µg/L to 100.0 mg/L

Chromium, Total

0.01 to 0.70 mg/L

Phosphorus, Total

0.06 to 100.0 mg/L

Cobalt

0.01 to 2.00 mg/L

Potassium

0.1 to 7.0 mg/L

Color

3 to 500 units

Quaternary Ammonium

Compounds

0.2 to 5.0 mg/L

COD

(Chemical Oxygen Demand)

0.7 to 15,000 mg/L

Selenium

0.01 to 1.00 mg/L

Copper

1 µg/L to 8.0 mg/L

Silica

3 µg/L to 100 mg/L

Cyanide

0.002 to 0.240 mg/L

Silver

0.005 to 0.700 mg/L

Cyanuric Acd

5 to 50 mg/L

Sulfate

2 to 900 mg/L

DEHA

(Diethylhydroxylamine)

3 to 450 µg/L

Sulfide

5 to 800 µg/L

Dissolved Oxygen

6 µg/L to 40 mg/L

Surfactants, Anionic

0.002 to 0.275 mg/L

Erythorbic Acid

(Isoascorbic acid)

13 to 1500 µg/L

Suspended Solids

5 to 750 mg/L

Fluoride

0.02 to 2.00 mg/L

Tannin and Lignin

0.1 to 9.0 mg/L

Formaldehyde

3 to 500 µg/L

TOC (Total Organic Carbon)

0.3 to 700 mg/L

Hardness, Total

4 µg/L to 4.00 mg/L

Tolyltriazole

1.0 to 20.0 mg/L

(Calcium & Magnesium as CaCO3)

Toxicity

0 to 100% Inhibition

Hydrazine

4 to 600 µg/L

TTHM (Trihalomethanes,Total)

10 to 600 µg/L

Hydroquinone

9 to 1000 µg/L

TPH

(Total Petroleum Hydrocarbons)

2 to 200 ppm,

threshold

Iodine

0.07 to 7.00 mg/L

Volatile Acids

27 to 2800 mg/L

Iron, Ferrous

0.02 to 3.00 mg/L

Zinc

0.01 to 3.00 mg/L

Iron, Total

0.009 to 6.0 mg/L

PT. Mora Anugerah Berkat sudah berpengalaman menyediakan dan mensupply alat instrument/analitik dari HACH DR 3900 Spectrophotometer,kami juga menyediakan berbagai aksessoris dan sparepart dari Spectrophotometry HACH DR 3900 dan mensupport layanan seperti re-training penggunaan Spectrophotometer HACH, jasa perawatan (Maintenance), Jasa Perbaikan (Service) dan mensupport (membantu) untuk kalibrasi dan lain – lain jangan ragu menghubungi kami.

Jual Laboratory HACH DR3900

 

 

HACH DR3900 Spectrophotometer