Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the uncanny-automator domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/moraanug/public_html/wp-includes/functions.php on line 6121
HACH DR6000 UV-VIS SPECTROPHOTOMETER

HACH DR6000 UV VIS SPECTROPHOTOMETER

 

 

 

 

 

HACH DR6000 UV VIS SPECTROPHOTOMETER

 

 

 

 

 

 

 

HACH DR6000 UV VIS SPECTROPHOTOMETER

 

The DR6000™ is the industry’s most advanced laboratory Spectrophotometer for water testing. It offers high-speed wavelength scanning across theUV and Visible Spectrum, and comes with over 250 pre-programmed methods including the most common water and environmental testing methods used today. With optional accessories allowing for high-volume testing via a carousel sample changer, and increased accuracy with a sample delivery system that eliminates optical difference errors, this instrument ensures you are ready to handle your wide-ranging water testing needs.

Combining the DR6000 with Hach’s unique TNTplus reagent vials, you gain additional accuracy with guided step-by-step testing procedures, while making scratched, flawed or dirty glassware a non-issue due to averaging 10 readings and discarding outliers. The instrument also utilizes RFID technology, allowing it to let you know automatically if your TNTplus reagents have expired, while detecting coefficient factors to avoid errors which can occur in lot-to-lot variations in the chemistries.

Partnering all of these features with an integrated QA software package allows for scheduling, documenting and interpreting your needed quality measurements.

HACH DR6000 UV VIS SPECTROPHOTOMETER

 

DR6000 UV VIS Spectrophotometer

Specification

Data Logger

5000 data points (result, date, time, sample-ID, user-ID)

Display

TFT 7 inch WVGA color touch

Enclosure Rating

IP20 with closed lid

Interfaces

USB type A (2), USB type B, Ethernet, RFID module

Manual Languages

en, es, fr, ja, ko, pt, zh

Operating Conditions

10 – 40 °C, max. 80% relative humidity (non-condensing)

Operating Mode

Transmittance (%), absorbance and concentration (wavelength, time)

Optical System

Reference beam, spectral

Photometric Accuracy

5 mAbs @ 0.0 – 0.5 Abs

<1% @ 0.5 – 2.0 Abs @ 546 nm

Photometric Linearity

0.005 – 2 Abs

≤ 0.01 at > 2 Abs with neutral glass at 546 nm

Photometric Measuring Range

± 3 Abs

Power Requirements

100 – 240 V; 50/60 Hz

Preprogrammed Methods

> 240

Region

Region:US

Sample Cell Compatibility

Rectangular : 10, 20, 30, 50 mm, 1 inch; round : 13 mm, 16 mm, 1 inch

Optional 100 mm rectangular cell with additional adapter

Scanning Speed

900 nm/min (in 1 nm steps)

Source Lamp

Tungsten (visible range), deuterium (UV range)

Specific Technology

RFID for easy method update, sample ID and Certificate of Analysis

Spectral Bandwidth

2 nm

Storage conditions

-25 to 60 °C / max. 80% relative humidity (non-condensing)

Stray Light

KI-solution at 220 nm < 3.3 Abs/ < 0.05%

User Interface Languages

bg, cn, cz, da, en, es, fr, gr, hr, hu,

it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr

User Programs

200

Warranty

12 months

Wavelength Accuracy

± 1 nm

Wavelength Range

190 – 1100 nm

Wavelength Reproducibility

< 0.1 nm

Wavelength Resolution

0.1 nm

Wavelength Selection

Automatic, based on method selection

Weight

Weight:11 kg

Click Here : HACH Global Product For Beverage

Click Here : HACH General Product Water Analysis For Industrial

Parameter/Range/Reagent Information

Alkalinity

Method

Range

10239 TNTplus

25 – 400 mg/L as CaCO₃

Aluminum

Method

Range

10215 TNTplus

0.02 – 0.50 mg/L Al

8012 Spectrophotometer, Powder Pillows

0.008 – 0.800 mg/L Al

8326 Eriochrome Cyanine R

0.006 – 0.250 mg/L Al

Ammonia

Method

Range

10023 Test ‘N Tube LR Salicylate

0.02 – 2.50 mg/L NH3-N

10031 Test ‘N Tube HR Salicylate

0.4 – 50.0 mg/L NH3-N

10205 HR TNTplus 832

2 – 47 mg/L NH3-N

10205 LR TNTplus 831

1 – 12 mg/L NH3-N

10205 UHR TNTplus 833

47 – 130 mg/L NH₃-N

10205 ULR TNTplus 830

0.015 – 2.00 mg/L NH₃-N

8038 Nessler

0.02 – 2.50 mg/L NH₃-N

8155 Powder Pillows Salicylate

0.01 – 0.50 mg/L NH₃-N

Ammonia, Free

Method

Range

10200 Spectrophotometer Powder Pillows

0.01 – 0.50 mg/L NH₃-N

10201 Spectrophotometer Powder Pillows Indophenol Method

0.01 – 0.50 mg/L NH₃-N

Anammox
Activity

Method

Range

10304 TNTplus 882

0 – 1000 mAbs (milli absorptions)

10304 TNTplus 882

0 – 33.4 µmol/L

(Cytochrome C from horse heart)

Arsenic

Method

Range

8013

0 – 0.200 mg/L As

Barium

Method

Range

10251 Spectrophotometer Powder Pillows

2 – 10,000 mg/L Ba

8014 Turbidimetric

2 – 100 mg/L Ba

Benzotriazole /
Tolyltriazole

Method

Range

8079 Powder Pillows UV Photolysis

1.0 – 16.0 mg/L Benzotriazole

8079 Powder Pillows UV Photolysis

1.0 – 20.0 mg/L Tolyltriazole

Boron

Method

Range

10252 Carmine Method Powder Pillows

2 – 50 mg/L B

10274 TNTplus 877

0.05 – 2.5 mg/L B

8015 Carmine

0.2 – 14.0 mg/L B

Bromine

Method

Range

8016 DPD Method, PP or AccuVac

0.05 – 4.50 mg/L Br₂

Cadmium

Method

Range

10217 TNTplus

0.02 – 0.30 mg/L Cd

8017 Dithizone

0.7 – 80 µg/L Cd

Cationic
Surfactants

Method

Range

10305 TNTplus 885

0.2 – 2.0 mg/L

Cetyltrimethylammonium bromide

Chloride

Method

Range

10291 Chloride TNTplus

1.0 – 70 mg/L Cl⁻

10291 Chloride TNTplus

70 – 1000 mg/L Cl⁻

8113

0.1 – 25.0 mg/L Cl⁻

Chlorine Dioxide

Method

Range

10126 DPD

0.05 – 5.00 mg/L ClO₂

10126 DPD Powder Pillows or AccuVac

0.04 – 5.00 mg/L ClO2

8065 LR Chlorophenol Red

0.01 – 1.00 mg/L ClO2

8138 Spectrophotometer HR Direct Reading

5 – 1000 mg/L

8345 MR Direct Reading Method Direct Reading

1 – 50.0 mg/L ClO₂

Amaranth

20 – 500 µg/L

Chlorine, Free

Method

Range

10059 DPD Rapid Liquid Method,

Pour-Thru Cell™ DPD Rapid Liquid Method for Free Chlorine

0.02 – 2.00 mg/L Cl₂

10069 DPD, HR Powder Pillows

0.1 – 10.0 mg/L Cl2

10102 DPD Test ‘N Tube

0.09 – 5.00 mg/L Cl2

10231 Spectrophotometer,TNTplus DPD

0.05 – 2.00 mg/L Cl2

10241 Powder Pillows Indophenol

0.04 – 4.50 mg/L Cl₂

10245 DPD, MR Powder Pillows

0.05 – 4.00 mg/L Cl2

8021 DPD Powder Pillows or AccuVac®

0.02 – 2.00 mg/L Cl2

Chlorine, Total

Method

Range

10014 DPD

2 – 500 µg/L ULR as Cl2

10060 DPD Rapid Liquid, Pour-Thru Cell

0.02 – 2.00 mg/L Cl₂

10070 DPD Powder Pillows

0.1 – 10.0 mg/L as Cl₂

10101 DPD Test ‘N Tube

0.09 – 5.00 mg/L Cl₂

10232 Spectrophotometer DPD TNTplus DPD

0.05 – 2.00 mg/L Cl2

10250 DPD Powder Pillows

0.05 – 4.00 mg/L Cl2

8167 DPD Powder Pillows or AccuVac®

0.02 – 2.00 mg/L Cl₂

8370 DPD

2 – 500 µg/L – as Cl₂

Chromium,
Hexavalent

Method

Range

8023 1,5-Diphenylcarbohydrazide

0 – 1.00 mg/L Cr6+

8023 Powder Pillows or AccuVac®

0.010 – 0.700 mg/L Cr6+

Chromium,
Hexavalent
and Total

Method

Range

10218 Hexavalent, TNTplus

0.03 – 1.00 mg/L Cr

Chromium,
Total

Method

Range

8024 Spectrophotometer Powder Pillows

0.01 – 0.70 mg/L Cr

Cobalt

Method

Range

8078 Spectrophotometer Powder Pillows

0.01 – 2.00 mg/L Co

COD (Chemical
Oxygen Demand)

Method

Range

10067 (Manganese III without chloride removal)

Spectrophotometer Manganese III Reactor Digestion Method

30 – 1,000 mg/L

10211 TNTplus ULR

1.0 – 60.0 mg/L

10212 TNTplus (UHR)

5 – 60 g/L COD (UHR)

10212 TNTplus UHR

250 – 15,000 mg/L

10236 TNTplus HR Mercury-Free Reactor Digestion

25 – 1,000 mg/L

10299 TNTplus 815

7 – 70 mg/L COD (LR)

10299 TNTplus 816

70 – 700 mg/L COD (HR)

8000 Reactor Digestion

0.7 – 40.0 mg/L

8000 Reactor Digestion

20 – 1500 mg/L

8000 Reactor Digestion

200 – 15,000 mg/L

8000 Reactor Digestion

3 – 150 mg/L

8000 TNTplus LR, HR

20 – 1,500 mg/L HR

8000 TNTplus LR, HR

3 – 150 mg/L LR

Color

Method

Range

10048 ADMI Weighted Ordinate ADMI Weighted Ordinate

5 – 1000 Pt-Co units

8025 True and Apparent, Spectrophotometer LR Color, True and Apparent, Low Range

3 – 200 Units

Copper

Method

Range

10238

0.1 – 8.0 mg/L Cu

8026 CuVer 2 AccuVac® Bicinchoninate

0.04 – 5.00 mg/L Cu

8143 Powder Pillows

1 – 210 µg/L Cu

8506 CuVer 1 Powder Pillows Bicinchoninate

0.04 – 5.00 mg/L Cu

Cyanide

Method

Range

10265 Pyridine Barbituric Acid

0.01 – 0.60 mg/L CN-

8027 Powder Pillows Pyridine-Pyrazalone

0.002 – 0.240 mg/L CN-

Detergents /
Surfactants

Method

Range

8028 Spectrophotometer, Crystal Violet

0.002 – 0.275 mg/L as LAS

Dissolved
Oxygen

Method

Range

8166 AccuVac® HR HRDO

0.3 – 15.0 mg/L O2

8316 Spectrophotometer AccuVac® Indigo Carmine

6 – 800 µg/L O2

8333 Ultra High Range, AccuVac

1.0 – 40.0 mg/L O₂

Fluoride

Method

Range

10225 SPADNS 2

0.1 – 2.0 mg/L

10225 SPADNS 2, Reagent Solution or AccuVac

0.02 – 2.00 mg/L F-

10225 SPADNS 2, TNTplus 878

0.1 – 2.5 mg/L F

8029 Reagent Solution or AccuVac

0.02 – 2.00 mg/L F-

Formaldehyde

Method

Range

10295 Formaldehyde TNTplus

0.5 – 10.0 mg/L H₂CO

8110 MBTH

3 – 500 µg/L CH2O

Hardness

Method

Range

10293 Hardness, Calcium/Magnesium

20 – 350 mg/L CaCO3

10293 Hardness, Calcium/Magnesium

Hardness, Ca/Mg 10293 3-50 mg/L Mg

10293 Hardness, Calcium/Magnesium

Hardness,

Ca/Mg 10293 5-100 mg/L Ca

8030 Ca & Mg Calmagite Colorimetric

Calmagite Colorimetric

0.05 – 4.00 mg/L Ca and

Mg as CaCO3

8374 Chlorophosonazo Rapid liquid,

Pour-Thru Cell Chlorophosphonazo Colorimetric

4 – 1,000 µg/L CaCO₃

8374 Chlorophosphonazo Colorimetric, Solution Pillow

8 – 1,000 µg/L CaCO3

Hydrazine

Method

Range

8141 Spectrophotometer, Reagent Solution or AccuVac  p-Dimethylaminobenzaldehyde

4 – 600 µg/L N2H4

Hydrogen
Peroxide

Method

Range

10290 Powder Pillows

0.1 – 10.0 mg/L PAA / H2O2

Iodine

Method

Range

8031 Spectrophotometer, Powder Pillows or AccuVac DPD

0.07 – 7.00 mg/L I₂

Iron

Method

Range

10229 TNTplus™

0.2 – 6.0 mg/L Fe

10249 FerroVer® Powder Pillows

0.1 – 300.0 mg/L Fe

10306 HPT251 (Metal Prep Set TNT890)

0.01 – 1.00 mg/L Fe

10306 HPT251 (Metal Prep Set TNT890)

0.012 – 1.200 mg/L Fe

8008 FerroVer® Powder Pillows or AccuVac

0.02 – 3.00 mg/L Fe

8112 Spectrophotometer Powder Pillows or AccuVac

0.012 – 1.800 mg/L Fe

8112 TPTZ

0.01 – 1.70 mg/L Fe

8146 Powder Pillows or AccuVac® 1,10 Phenanthroline

0.02 – 3.00 mg/L Fe2+

8147 FerroZine® Solution Pillows

0.009 – 1.400 mg/L Fe

8147 Spectrophotometer FerroZine® Rapid Liquid,Pour Thru Cell FerroZine

0.009 – 1.400 mg/L Fe

8365 FerroMo® Powder Pillows FerroMo

0.01 – 1.80 mg/L Fe

FerroZine

1.00 – 100 µg/L

Lead

Method

Range

10216 Spectrophotometer TNTplus™

0.1 – 2.0 mg/L Pb

8033 Spectrophotometer Powder Pillows Dithizone

3 – 300 µg/L Pb

8317 Spectrophotometer LeadTrak™

Column Extraction LeadTrak Fast Column Extraction

5 – 150 µg/L Pb

Magnesium,
Total

Method

Range

10292 TNTplus

0.5 – 10 mg/L Mg

10292 TNTplus

10 – 50 mg/L

Manganese

Method

Range

8034 Periodate Oxidation

0.2 – 20 mg/L Mn

8034 Powder Pillows Periodate Oxidation

0.1 – 20.0 mg/L Mn

8149 PAN

0.01 – 0.70 mg/L Mn

8149 Powder Pillows PAN Method

0.006 – 0.700 mg/L Mn

Mercury

Method

Range

10065 Cold Vapor Mercury Concentration

0.1 – 2.5 µg/L Hg

Molybdenum

Method

Range

8036 Mercaptoacetic Acid

0.3 – 40.0 mg/L Mo

8036 Powder Pillows or AccuVac Mercaptoacetic Acid

0.2 – 40.0 mg/L Mo

8169 Powder Pillows Ternary Complex

0.02 – 3.00 mg/L Mo

Monochloramine

Method

Range

10171 Indophenol LR, Powder Pillows

0.04 – 4.50 mg/L Cl₂

10172 Indophenol Method Test ‘N Tube

0.1 – 10.0 mg/L Cl₂

10200 Monochloramine/Free Ammonia Powder Pillows

0.01 – 0.50 mg/L NH₃-N

10200 Monochloramine/Free Ammonia Powder Pillows

0.04 – 4.50 mg/L Cl2

Nickel

Method

Range

10220 Spectrophotometer, TNTplus

0.1 – 6.0 mg/L Ni

8037 Spectrophotometer Powder Pillows Heptoxime

0.02 – 1.80 mg/L Ni

8150 1-(2 Pyridylazo)-2 Napthol (PAN)

0.01 – 1.00 mg/L Ni

8150 1-(2 Pyridylazo)-2 Napthol (PAN)

0.02 – 2.00 mg/L Co

8150 Powder Pillows PAN

0.006 – 1.000 mg/L Ni

Nitrate

Method

Range

10020 Spectrophotometer,

Test ‘T Tube Chromotropic Acid Method

0.2 – 30.0 mg/L NO3–N

10049 Spectrophotometer, UV Screening UV Screening

0.1 – 10.0 mg/L

10206 Spectrophotometer, HR, TNTplus 836

22 – 155 mg/L NO3

10206 Spectrophotometer, HR, TNTplus 836

5 – 35 mg/L NO₃⁻-N

10206 Spectrophotometer, LR, TNTplus 835

.23 – 13.50 mg/L NO₃⁻-N

10206 Spectrophotometer, LR, TNTplus 835

1.00 – 60.00 mg/L NO3

8039 Powder Pillows or AccuVac® Cadmium Reduction

0.3 – 30.0 mg/L NO3–N

8171 Spectrophotometer Powder Pillows or AccuVac

0.1 – 10.0 mg/L NO3–N

8192 Powder Pillows LR Cadmium Reduction

0.01 – 0.50 mg/L NO3–N

Nitrite

Method

Range

10019 Test ‘N Tube Vials Diazotization

0.003 – 0.500 mg/L NO2–N

10207 Spectrophotometer, TNTplus 839

0.015 – 0.600 mg/L NO2–N

10237 Spectrophotometer, TNTplus™ 840

0.6 – 6.0 mg/L NO2–N

(2.0-20.0 mg/L NO₂-)

10296 Diazotization Method, TNTplus™ 841

2 – 90 mg/L NO₂⁻-N

10296 Diazotization Method, TNTplus™ 841

7 – 295 mg/L NO₂⁻-(UHR)

8153 Spectrophotometer HR, Powder Pillows

2 – 250 mg/L NO2-

8507 Diazotization

0.02 – 0.30 mg/l NO2-N

8507 Spectrophotometer Powder Pillows or AccuVac®

0.002 – 0.300 mg/L NO2–N

Nitrogen,
Ammonia

Method

Range

10301 Salicylate TNTplus (UHR)

100 – 1800 mg/L NH3-N

10301 Salicylate TNTplus (UHR)

120 – 2190 mg/L NH3

Nitrogen, Total

Method

Range

10071 Test ‘N Tube LR Persulfate Digestion

0.5 – 25.0 mg/L N

10072 Test ‘N Tube HR Persulfate Digestion

2 – 150 mg/L N

10208 Spectrophotometer HR TNTplus

5 – 40 mg/L N

10208 Spectrophotometer LR TNTplus

1 – 16 mg/L N

10208 Spectrophotometer UHR TNTplus

20 – 100 mg/L N

Nitrogen,
Total Inorganic (TIN)

Method

Range

10021 Test ‘N Tube™ Titanium Trichloride Reduction

0.2 – 25.0 mg/L N

Nonionic
Surfactants

Method

Range

10275 Nonionic surfactants TNT875

0.2 – 6.0 mg/L TRITON X-100

10275 Nonionic surfactants TNT876

6.0 – 200 mg/L TRITON x 100

Organic
Constituents

Method

Range

10054

Organic Constituents 10054

absorbance per centimeter

Oxygen
Scavengers

Method

Range

8140 Powder Pillows Iron Reduction

13 – 1500 µg/L Iso-ascorbic Acid (ISA)

8140 Powder Pillows Iron Reduction

15 – 1,000 µg/L

Methylethyl Ketoxime (MEKO)

8140 Powder Pillows Iron Reduction

3 – 450 µg/L DEHA

8140 Powder Pillows Iron Reduction

5 – 600 µg/L Carbohydrazide

8140 Powder Pillows Iron Reduction

9 – 1,000 µg/L Hydroquinone-PP

Ozone

Method

Range

8311 AccuVac® Indigo

0.01 – 0.25 mg/L O₃ LR

8311 AccuVac® Indigo

0.01 – 0.75 mg/L O3

8311 AccuVac® Indigo

0.01 – 1.50 mg/L O₃ HR

Peracetic Acid (PAA)

Method

Range

DPD 10290

0.10 – 10.0 mg/L as PPA

Phenols

Method

Range

10266 4-Aminoantipyrine, TNTplus 868

20 – 150 mg/L Phenol

10266 4-Aminoantipyrine, TNTplus 868

5 – 40 mg/L Phenols

8047 4-Aminoantipyrine

0.002 – 0.200 mg/L Phenol

Phosphonates

Method

Range

8007 Powder Pillows Persulfate UV Oxidation

0.02 – 2.50 mg/L PO43-

8007 Powder Pillows Persulfate UV Oxidation

0.1 – 2.5 mg/L

8007 Powder Pillows Persulfate UV Oxidation

1.0 – 125 mg/L PO43-

Phosphorus

Method

Range

10055 Spectrophotometer Pour-Thru Cell

19 – 3,000 µg/L PO₄

10127 Test ‘N Tube Molybdovanadate

with Acid Persulfate Digestion

1.0 – 100.0 mg/L PO4 3­

10209 Spectrophotometer HR, TNTplus 844

0.5 – 5 mg/L P (1.5-15.0 mg/L PO₄)

10209 Spectrophotometer LR, TNTplus 843

0.05 – 1.5 mg/L P (0.15-4.5 mg/L PO₄)

10209 Spectrophotometer UHR, TNTplus 845

2 – 20 mg/L P (6-60 mg/L PO₄)

10209 Spectrophotometer ULR, TNTplus 843

10 – 500 µg/L P (30-1500µg/L PO₄)

10210 Spectrophotometer HR, TNTplus 844

1.5 – 15.0 mg/L PO43-

10210 Spectrophotometer LR, TNTplus 843

0.15 – 4.50 mg/L PO43-

10210 Spectrophotometer UHR,

TNTplus 845 Ascorbic Acid Method TNTplus™ 843

6 – 60 mg/L PO43-

10214 Spectrophotometer TNTplus 846

1.6 – 30 mg/L P

(5.0 – 90 mg/L PO₄)

10307 Orthophosphate Ascorbic Acid

0.01 – 0.50 mg/L PO₄-P

8048 Powder Pillows or AccuVac® PhosVer 3,

Ascorbic Acid

0.02 – 2.50 mg/L PO4

8048 TNT™ PhosVer 3

0.06 – 5.00 mg/L PO4 ³⁻

8114 Reagent or AccuVac Molybdovanadate

0.3 – 45.0 mg/L PO4

8114 Spectrophotometer Pour-Thru

0.3 – 45.0 mg/L PO4

8114 Test ‘N Tube HR Molybdovanadate

1.0 – 100.0 mg/L PO4

8178 Amino Acid Reagent Amino Acid Method

0.23 – 30.00 mg/L PO4

8180 Test ‘N Tube™ PhosVer® 3 with Acid Aydrolysis

0.06 – 3.50 mg/L PO4 3­

8190 Digestion Test ‘N Tube™

0.06 – 3.50 mg/L PO4 3­

Potassium

Method

Range

8049 colorimetric Powder Pillow-LR-MR-HR

For oil and gas field waters

0.1 – 700 mg/L K

8049 Spectrophotometer Powder Pillows

0.1 – 7.0 mg/L K

Quaternary Ammonium
Compounds

Method

Range

8337 Spectrophotometer Powder

Pillows Direct Binary Complex

0.2 – 5.0 mg/L CTAB

Selenium

Method

Range

8194 Spectrophotometer Diaminobenzidine

0.01 – 1.00 mg/L Se

Silica

Method

Range

8185 Spectrophotometer Powder

Pillows HR Silicomolybdate

1 – 100 mg/L SiO2

8186 Spectrophotometer Powder

Pillows Heteropoly Blue

0.010 – 1.600 mg/L SiO2

8282 Spectrophotometer Pour-Thru

Cell Heteropoly Blue

3 – 1,000 µg/L SiO2

8282 Spectrophotometer Pour-Thru Cell-

Rapid Liquid Heteropoly Blue Rapid Liquid

3 – 1000 µg/L as SiO₂

Silver

Method

Range

8120 Spectrophotometer Powder Pillows Colorimetric

0.02 – 0.70 mg/L

Sulfate

Method

Range

10227 Spectrophotometer HR TNTplus 865

150 – 900 mg/L SO4

10227 Spectrophotometer LR TNTplus 864 Turbidimetric

40 – 150 mg/L SO4

10248 Powder Pillows LR-MR-HR SulfaVer 4

2 – 7000 mg/L SO₄ ²-

8051 Powder Pillows or AccuVac® SulfaVer 4

2 – 70 mg/L SO42-

Sulfide /
Hydrogen Sulfide

Method

Range

10254 Methylene Blue

0.01 – 70 mg/L S²-

10294 Methylene Blue

0.1 – 2.0 mg/L S²-

8131 Spectrophotometer Methylene Blue

5 – 800 µg/L S2-

Sulfite

Method

Range

10308 DTNB

0.10 – 5.00 mg/L SO₃²¯

Suspended Solids

Method

Range

8006 Photometric

5 – 750 mg/L TSS

Tannin and Lignin

Method

Range

8193 Tyrosine

0.1 – 9.0 mg/L as Tannic Acid

TKN

Method

Range

10242 Spectrophotometer, s-TKN, TNTplus 880

0 – 16 mg/L N

8075 TKN, Nessler

1 – 150 mg/L TKN

Total Organic
Carbon
(TOC)

Method

Range

10128 HR, Spectrophotometer Test ‘N Tube Direct

100 – 700 mg/L C

10129 LR, Test ‘N Tube Direct

0.3 – 20.0 mg/L C

10173 MR, Test ‘N Tube Direct

15 – 150 mg/L C

10267 HR Spectrophotometer TNTplus 811

30 – 300 mg/L C

10267 LR Spectrophotometer TNTplus 810

1.5 – 30.0 mg/L C

Toxicity

Method

Range

10017 ToxTrak

0 – 100 % Inhibition

TPH in Soil

Method

Range

10050

TPH in Soil 10050 Threshold

Trihalomethanes,
Total (THM)

Method

Range

10132 THM Plus

10 – 600 µg/L CHCl₃

Volatile Acids

Method

Range

10240 TNTplus

50 – 2,500 mg/L Acetic

8196 Reagent Solution Esterification

27 – 2800 mg/L as Acetic Acid

Zinc

Method

Range

8009 Powder Pillows Zincon

0.01 – 2.00 mg/L Zn

8009 Powder Pillows Zincon

0.01 – 3.00 mg/L Zn

PT. Mora Anugerah Berkat sudah berpengalaman menyediakan dan mensupply alat instrument/analitik dari HACH DR 3900 Spectrophotometer,kami juga menyediakan berbagai aksessoris dan sparepart dari Spectrophotometry HACH DR 3900 dan mensupport layanan seperti re-training penggunaan Spectrophotometer HACH, jasa perawatan (Maintenance), Jasa Perbaikan (Service) dan mensupport (membantu) untuk kalibrasi dan lain – lain jangan ragu menghubungi kami.

HACH DR 3900 Spectrophotometer

Untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di :

author avatar
admin
Verified by MonsterInsights