Benchtop HACH DR3900 Spectrophotometer
Benchtop HACH DR3900 Spectrophotometer
Simplicity throughout: The DR3900 Spectrophotometer provides the simplest way to perform tests for water analysis. Used together with TNTplus™ test kits testing steps are reduced. The potential for human errors is minimized. The system of Spectrophotometer and test kits supports the process optimization of waste water treatment plants and environmental testing.This instrument connects to Claros, Hach’s innovative Water Intelligence System, enabling you to seamlessly connect and manage instruments, data, and process – anywhere, anytime. The result is greater confidence in your data and improved efficiency in your operations. To unlock the full potential of Claros, insist on Claros Enabled instruments.
Berikut ini tautan / link product dari HACH Spectrophotometer Series :
-
Click Here : HACH General Catalog
-
Click Here : HACH DR6000 UV-Vis Spectrophotometer Brochure
-
Click Here : HACH DR3900 Spectrophotometer Brochure
-
Click Here : HACH DR1900 Portable Spectrophotometer Brochure
-
Click Here : Thermo Scientific Genesys Spectrophotometer Brochure
Benchtop HACH DR3900 Spectrophotometer
Simple Preparation
TNTplus vials use DosiCaps that are easier to use than Powder Pillows or Liquid Reagents, without any risk of contamination.
The boxes and vials are color-coded for fast and easy parameter and range recognition of exactly the test you need.
Step-by-step illustrated test methods are printed on the box as quick reference or can be called up in the instrument menu.
Fast execution
A 2D barcode on the TNTplus vial is automatically read by the Hach DR spectrophotometer to identify the appropriate method and take the measurement. The vial spins to take 10-fold absorbance readings that will be averaged for result determination to exclude scratches and fingerprints. Instrument calibration verification and high instrument stability all combine to eliminate the need to run reagent blanks.
Comprehensive Documentation
Measurement results are documented on the detailed level with timestamp, operator ID, absorbance reading, and calculated concentration. The 2D barcode delivers the lot number and expiry date, logged with every result.
*RFID technology currently available in the US, Puerto Rico, Austrailia, New Zealand, and Colombia only.
Customisable
With the ability to store hundreds of user-determined methods, operators are able to tailor the DR3900 to meet the everyday needs of the plant.
Being able to optimise and customise the method portfolio, combined with regular software updates and Claros connectivity, makes the DR3900 the ultimate solution to water quality lab needs.
Benchtop HACH DR3900 Spectrophotometer
HACH DR 3900 SPECTROPHOTOMETER |
|
Specification |
|
Beam Height |
10 mm |
Data Logger |
2000 measured values (Result, Date, Time, Sample ID, User ID) |
Display |
7″ TFT |
Display Resolution |
WVGA (800 pix x 480 pix) |
Display Size |
7 inch (17.8 cm) |
Display Type |
Colored touch-screen |
Enclosure Rating |
IP30 |
Includes |
Adapter A for 1 in. round and 1 cm square cells, matched pair of 1 in.square glass sample cells, light shield, dust cover, printed basicuser manual and benchtop power supply with 115 and 230V power cords. |
Interfaces |
|
Manual Languages |
English,French (CDN),Spanish (SA),Portuguese (BR), Chinese, Japanese, Korean |
Max. Operating Humidity |
80 % |
Max. Storage Humidity |
80 % |
Operating Conditions |
10 – 40 °C |
Operating Mode |
Transmittance (%), Absorbance and Concentration, Scanning |
Optical System |
Reference beam, spectral |
Photometric Accuracy |
5 mAbs @ 0.0 – 0.5 Abs |
Photometric Accuracy 2 |
1 % at 0.50 – 2.0 Abs |
Photometric Linearity |
< 0.5% – 2 Abs ; 2 Abs with neutral glass at 546 nm |
Photometric Measuring Range |
± 3.0 Abs (wavelength range 340 – 900 nm) |
Power Requirements |
With external power supply |
Power Requirements (Hz) |
Power requirements (Hz):50/60 Hz |
Power Requirements (Voltage) |
Power requirements (Voltage):110 – 240 V AC |
Power Supply |
Benchtop Power Supply |
Preprogrammed Methods |
> 240 |
Region:US |
Region:US |
Sample CellCompatibility |
Rectangular : 10 mm, 50 mm, 1 inch;round: 13 mm, 16 mm, 1 inch |
Source Lamp |
Gas-filled Tungsten (visible) |
Specific Technology |
RFID not applicable with this model |
Spectral Bandwidth |
5 nm ± 1 nm |
Standard Accessories |
None |
Storage Conditions |
-30 – 60 °C |
Stray Light |
< 0.1% T at 340 nm with NaNO2 |
User InterfaceLanguages |
Bulgarian, Chinese, Croatian, Czech, Danish,Dutch, English, Finnish,French, German, Greek, Hungarian, Italian, Japanese, Korean,Polish,Portuguese – Brazil, Portuguese, Russian, Serbian, Slovakian,Slowenian, Spanish, Swedish, Turkish |
User Programs |
100 |
Warranty |
12 months |
Wavelength Accuracy |
± 1.5 nm (wavelength range 340 – 900 nm) |
Wavelength Calibration |
Automatic |
Wavelength Range |
320 – 1100 nm |
Wavelength Reproducibility |
± 0.1 nm |
Wavelength Resolution |
1 nm |
Wavelength Selection |
Automatic |
Weight |
4.2 kg |
Available Tests
The following table lists available tests and overall ranges for the Hach DR 3900 Benchtop Spectrophotometer. The ranges may represent more than one available test for the instrument. Consult your Hach representative, Customer Service, the Hach Master Catalog, or the Hach web site at www.hach.com for complete details of all available tests for this instrument.
Parameter |
Range |
TNTplus Range Test Parameter |
Range |
Alachlor |
0.1 to 0.5 ppb, |
Lead |
3 µg/L to 2.0 mg/L |
Alkalinity, Total |
25 to 400 mg/L |
Manganese |
0.006 to 20.0 mg/L |
Aluminum |
0.002 to 0.800 mg/L |
Mercury |
0.1 to 2.5 µg/L |
Ammonia, Nitrogen |
0.015 to 50.0 mg/L |
Methylethylketoxime (MEKO) |
15 to 1000 µg/L |
Arsenic |
0.020 to 0.200 mg/L |
Molybdenum, Molybdate |
0.02 to 40.0 mg/L |
Atrazine |
0.5 to 3.0 ppb, |
Nickel |
0.006 to 6.0 mg/L |
Barium |
2 to 100 mg/L |
Nitrate, Nitrogen |
0.01 to 35 mg/L |
Benzotriazole |
1.0 to 16.0 mg/L |
Nitrite, Nitrogen |
0.002 to 250 mg/L |
Boron |
0.2 to 14.0 mg/L |
Nitrogen, Simplified Total Kjeldahl |
0 to 16 mg/L |
Bromine |
0.05 to 4.50 mg/L |
Nitrogen, Total |
0.5 to 150 mg/L |
Cadmium |
.7 µg/L to 0.30 mg/L |
Nitrogen, Total Inorganic |
0.2 to 25.0 mg/L |
Carbohydrazide |
5 to 600 µg/L |
Nitrogen, Total Kjeldahl |
1 to 150 mg/L |
Chloramine, Mono |
0.04 to 10.0 mg/L |
Ozone |
0.01 to 1.50 mg/L |
Chloride |
0.1 to 25.0 mg/L |
PCB (Polychlorinated Biphenyls) |
1 to 50 ppm, threshold |
Chlorine Dioxide |
0.01 to 1000 mg/L |
Phenols |
0.002 to 0.200 mg/L |
Chlorine, Free |
0.02 to 10.0 mg/L |
Phosphonates |
0.02 to 125.0 mg/L |
Chlorine, Total |
2 µg/L to 10.0 mg/L |
Phosphorus, Acid Hydrolyzable |
0.06 to 100.0 mg/L |
Chromium, Hexavalent |
0.010 to 1.00 mg/L |
Phosphorus, Reactive (Orthophosphate) |
19 µg/L to 100.0 mg/L |
Chromium, Total |
0.01 to 0.70 mg/L |
Phosphorus, Total |
0.06 to 100.0 mg/L |
Cobalt |
0.01 to 2.00 mg/L |
Potassium |
0.1 to 7.0 mg/L |
Color |
3 to 500 units |
Quaternary Ammonium Compounds |
0.2 to 5.0 mg/L |
COD (Chemical Oxygen Demand) |
0.7 to 15,000 mg/L |
Selenium |
0.01 to 1.00 mg/L |
Copper |
1 µg/L to 8.0 mg/L |
Silica |
3 µg/L to 100 mg/L |
Cyanide |
0.002 to 0.240 mg/L |
Silver |
0.005 to 0.700 mg/L |
Cyanuric Acd |
5 to 50 mg/L |
Sulfate |
2 to 900 mg/L |
DEHA (Diethylhydroxylamine) |
3 to 450 µg/L |
Sulfide |
5 to 800 µg/L |
Dissolved Oxygen |
6 µg/L to 40 mg/L |
Surfactants, Anionic |
0.002 to 0.275 mg/L |
Erythorbic Acid (Isoascorbic acid) |
13 to 1500 µg/L |
Suspended Solids |
5 to 750 mg/L |
Fluoride |
0.02 to 2.00 mg/L |
Tannin and Lignin |
0.1 to 9.0 mg/L |
Formaldehyde |
3 to 500 µg/L |
TOC (Total Organic Carbon) |
0.3 to 700 mg/L |
Hardness, Total |
4 µg/L to 4.00 mg/L |
Tolyltriazole |
1.0 to 20.0 mg/L |
|
(Calcium & Magnesium as CaCO3)
|
Toxicity |
0 to 100% Inhibition |
|
Hydrazine |
4 to 600 µg/L |
TTHM (Trihalomethanes,Total) |
10 to 600 µg/L |
Hydroquinone |
9 to 1000 µg/L |
TPH (Total Petroleum Hydrocarbons) |
2 to 200 ppm, threshold |
Iodine |
0.07 to 7.00 mg/L |
Volatile Acids |
27 to 2800 mg/L |
Iron, Ferrous |
0.02 to 3.00 mg/L |
Zinc |
0.01 to 3.00 mg/L |
Iron, Total |
0.009 to 6.0 mg/L |
Berikut ini tautan / link product dari HACH Spectrophotometer Series :
-
Click Here : HACH General Catalog
-
Click Here : HACH DR6000 UV-Vis Spectrophotometer Brochure
-
Click Here : HACH DR3900 Spectrophotometer Brochure
-
Click Here : HACH DR1900 Portable Spectrophotometer Brochure
-
Click Here : Thermo Scientific Genesys Spectrophotometer Brochure
PT. Mora Anugerah Berkat (M.A.B) adalah perusahaan yang sudah berpengalaman dalam menyediakan/mensupply peralatan laboratorium untuk general laboratory equipment dan water analysis equipment seperti Benchtop HACH DR3900 Spectrophotometer, kami juga menyediakan peralatan baik lokal maupun custom (khusus) yang sudah teruji dan sesuai dengan ASTM,kami juga menyediakan berbagai brand/merk internasional dari USA, Eropa dan China,produk internasional yang kami supply/tawarkan seperti : HACH, HANNA Inst, Thermo Scientific, YSI,HORIBA, ORION dan masih banyak lagi ; Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.
Benchtop HACH DR3900 Spectrophotometer
-
PT. Mora Anugerah Berkat (M.A.B)
-
Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang – Provinsi Banten
-
Phone : 021 7345.7064
-
Mobile: 0812.8140.0749 / 0812.8770.5470
-
Chat : Whats App, Line, WeChat ,Telegram
-
Website : www.moraanugerah.id – www.moraanugerah.com
-
Email : info@moraanugerah.com – info@moraanugerah.id – marketing_div@moraanugerah.com