Catalog Number |
GENESYS 40 Visible Spectrophotometer |
840-297000 |
|
Optical Design |
Dual beam |
Spectral Bandwidth |
5 nm |
Wavelength Range |
325 nm – 1100 nm |
Detector Type |
Dual Silicon Photodiodes |
Display |
7-inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
Photometric AccuracyInstrument |
± 0.002A at 0.5A ; ± 0.004A at 1.0A ; ±0.008A at 2.0A |
Printer |
Snap-on printer available |
Wavelength Accuracy |
± 0.5 nm |
Baseline Flatness |
± 0.005A |
Compartments |
|
Connections |
|
Description |
GENESYS 40 Visible Spectrophotometer |
Dimensions (L x W x H) |
35.5 x 38.5 x 19.5 cm |
Drift |
(At 500 nm after 1 hour warmup) <0.0010A/Hr |
ElectricalRequirements |
External AC to DC converter. Voltage and Frequency (Hz)selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
Keypad |
Touchscreen |
Lamp |
Tungsten-Halogen (>1000 hours) |
Noise |
(RMS at 500 nm 60 consecutive measurements) :≤0.00020A at 0A at 260 and 500 nm≤0.00030A at 1A at 260 and 500 nm≤0.00040A at 2A at 260 and 500 nm |
Optical Design |
Dual Beam |
Photometric Display |
-3A to +5A |
Photometric Range |
–3A to +3.5A |
Photometric Repeatability |
±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth |
5 nm |
Stray Light |
<0.05%T at 340 nm and 400 nm |
Wavelength Data Interval |
0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Range |
325 nm – 1100 nm |
Wavelength Repeatability |
< ±0.2 nm |
Wavelength Scan Speed |
Automatic – up to 1800 nm/min |
Weight (Metric) |
7.5 kg |
Unit Size |
Each |
Catalog Number |
GENESYS 50 UV-Vis Spectrophotometer |
840-298000 |
|
Optical Design |
Dual Beam |
Spectral Bandwidth |
2 nm |
Wavelength Range |
190 nm – 1100 nm |
Detector Type |
Dual Silicon Photodiodes |
Display |
7-inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
Photometric AccuracyInstrument |
±0.002A at 0.5A ±0.004A at 1.0A ±0.008A at 2.0A |
Printer |
Snap-on printer available |
Wavelength Accuracy |
±0.5 nm |
Baseline Flatness |
±0.002A |
Compartments |
# Accessible from top, front or side Able to accommodate cells up to 100mm cells
|
Connections |
# Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
|
Description |
GENESYS 50 UV-Vis Spectrophotometer |
Dimensions (L x W x H) |
35.5 x 38.5 x 19.5 cm |
Drift |
(At 500 nm after 1 hour warmup) <0.0005A/Hr |
ElectricalRequirements |
External AC to DC converter. Voltage and Frequency (Hz)selected automatically, 100 – 240 Volts, 50 – 60 Hz. |
Keypad |
Touchscreen |
Lamp |
Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
Noise |
(RMS at 500 nm 60 consecutive measurements)
|
Optical Design |
Dual beam |
Photometric Display |
-3A to +5A |
Photometric Range |
–2A to +3.5A |
Photometric Repeatability |
±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth |
2 nm |
Stray Light |
< 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2) |
Wavelength Data Interval |
0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Range |
190 nm – 1100 nm |
Wavelength Repeatability |
< ±0.2 nm |
Wavelength Scan Speed |
Slow, medium and fast – up to 1600 nm/min |
Weight (Metric) |
7.5 kg |
Unit Size |
Each |
Description |
GENESYS 30 |
GENESYS 40 |
GENESYS 140 |
GENESYS 50 |
GENESYS 150 |
BioMate 160 |
GENESYS 180 |
|
Optical Design |
Single Beam |
Dual Beam |
Double Beam |
|||||
Spectral Bandwidth |
5 nm |
2 nm |
||||||
Light Source(Typical Lifetime) |
Tungsten-Halogen (>1000 hours) |
Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
||||||
Detector |
Silicon Photodiode |
Dual Silicon Photodiodes |
||||||
Wavelength |
Range |
325–1100 nm |
190–1100 nm |
|||||
Accuracy |
±2 nm |
±0.5 nm |
||||||
Repeatability |
<±1 nm |
<±0.2 nm |
||||||
ScanSpeed |
Automatic – up to1200 nm/min |
Automatic – up to 1800 nm/min |
Slow, medium and fast (up to 1600 nm/min) |
|||||
DataResolution |
1 nm |
0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
0.1 nm, 0.2 nm, 0.5 nm,1 nm, 2 nm, 5 nm |
|||||
Photometric |
Range |
–3A to +3A |
–3A to +3.5A |
–2A to +3.5A |
||||
Display |
–3A to +3A, 0 to 200 000 %T,0 to 9 999 999 C |
–3A to +5A |
||||||
Accuracy |
± 0.002A (0 – 0.3A) 0.5 % ofABS reading (0.301A – 2.5A) |
± 0.002A at 0.5A± 0.004A at 1.0A± 0.008A at 2.0A |
||||||
Repeatability1 |
± 0.002 A |
± 0.001A at 1A |
||||||
Noise2 |
≤ 0.001A at 0A≤ 0.001A at 1A≤ 0.002A at 2A |
≤0.00020A at 0A at 260 and 500 nm≤0.00030A at 1A at 260 and 500 nm≤0.00040A at 2A at 260 and 500 nm |
||||||
Drift3 |
< 0.002A/Hr |
< 0.0010A/Hr |
<0.0005A/Hr |
|||||
Stray Light |
< 0.1%T at 340 nm and 400 nm |
< 0.05%T at 340 nm and 400 nm |
< 1.0 %T 198 nm (KCl) , < 0.05 %T at 220 nm (NaI),< 0.03 %T at 340 nm (NaNO2) |
|||||
Baseline Flatness |
< 0.003A |
± 0.005A |
± 0.002A |
|||||
Display |
5-inch diagonal, 32-bit color display,800 × 480 pixels |
7-inch color touchscreen,fixed, high definition,800 × 1280 pixels |
7-inch color touchscreen,tiltable, high definition,800 × 1280 pixels |
7-inch color touchscreen,fixed, high definition,800 × 1280 pixels |
7-inch color touchscreen, tiltable,high definition, 800 × 1280 pixels |
|||
Keypad |
Tactile rubber 23 keys with numeric keypad |
Touchscreen |
||||||
SampleCompartment |
• Accessible from top, front or side• All platforms can accommodate 100 mm cells• Available accessory for test-tubes up to 25 mmdiameter and 150 mm height• Removable, washable sample compartment linerwith magnetic placement and hold-down |
Accommodates (optional):• 8-position cell changer• 4-position cell changer(long path cells)• Peltier thermostattedcell holder (20–60 °C)• Sipper accessory |
• Accessible from top,front or side• Able to accommodatecells up to 100 mm pathlength• Available accessory for test-tubesup to 25 mm diameter and150 mm height• Removable, washable samplecompartment liner with magneticplacement and hold-down |
Accommodates (optional):• 8-position cell changer• 4-position cell changer(long path cells)• Peltier thermostattedcell holder (20–60 °C)• Sipper accessory• Fiber optic probe coupler |
• 8-position cell changer(standard) Alsoaccommodates (optional):• 4-position cell changer(long path cells)• Peltier thermostattedcell holder (20–60 °C)• Sipper accessory• Fiber optic probe coupler |
|||
Printer |
Snap-on printer available |
|||||||
Connectivity |
• USB-A on front face supports flash memory devices for method and data storage• USB-B on side supports connection to a Windows computer running optional remote control software; export data to PC via USB |
• Single USB-A supports flash memory devices for method and data storage• Duplex USB-A supports connection to a Windows computer running optional remote control software, keyboard, mouse• Export data to network or PC via Ethernet or Wi-Fi• Print via USB, Ethernet or Wi-Fi |
||||||
Languages |
English (Available soon: Spanish, German, French, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai) |
|||||||
Dimensions |
35.5 × 38.5 × 19.5 cm (L × W × H) |
|||||||
Weight |
7.5 kg |
|||||||
Power Requirements |
External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz. |
|||||||
Warranty |
1 (one) year |