Perform routine measurements for quality control or teaching in the chemistry classroom with rugged Thermo Scientific™ GENESYS™ 50 UV-Visible and GENESYS 40 Vis Spectrophotometers. Offered in a single cell configuration, these instruments are designed with a sloping surface to shed spills and a washable sampling compartment for easy clean up. A 7-inch touchscreen interface, local control software (no PC needed) and optional Wi-Fi networking make the GENESYS 50 UV-Vis or GENESYS 40 Vis Spectrophotometer the ideal choice for daily sampling purposes.

Thermo Scientific GENESYS™ 40 Vis/UV-Vis Spectrophotometers 

The GENESYS 50 is a dual beam UV-Vis spectrophotometer in a single-cell configuration that meets all of the specifications for critical quality control applications and precise chemical measurements. The GENESYS 40 Dual Beam Vis Spectrophotometer is a visible spectral region version in this instrumental class. Both  feature data resolution from 0.2 nm to 5 nm.

Click Here : Thermo Scientific GENESYS 40/50 UV/Vis Spectrophotometer Catalog

Catalog Number
GENESYS 40 Visible Spectrophotometer
840-297000
Optical Design Dual beam
Spectral Bandwidth 5 nm
Wavelength Range 325 nm – 1100 nm
Detector Type Dual Silicon Photodiodes
Display 7-inch color touchscreen, fixed, high definition, 800 × 1280 pixels
Photometric Accuracy
Instrument
± 0.002A at 0.5A    ;    ± 0.004A at 1.0A    ;    ±0.008A at 2.0A
Printer Snap-on printer available
Wavelength Accuracy ± 0.5 nm
Baseline Flatness ± 0.005A
Compartments # Accessible from top, front or side Able to accommodate cells up to 100mm cells
# Available accessory for test tubes up to 25 mm diameter and 150 mm height
# Removable, washable sample compartment liner with magnetic placement and hold-down
Connections # Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse
# Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available
Description GENESYS 40 Visible Spectrophotometer
Dimensions (L x W x H) 35.5 x 38.5 x 19.5 cm
Drift (At 500 nm after 1 hour warmup) <0.0010A/Hr
Electrical
Requirements
External AC to DC converter. Voltage and Frequency (Hz)
selected automatically, 100 – 240 Volts, 50 – 60 Hz.
Keypad Touchscreen
Lamp Tungsten-Halogen (>1000 hours)
Noise (RMS at 500 nm 60 consecutive measurements) :
≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm
Optical Design Dual Beam
Photometric Display -3A to +5A
Photometric Range –3A to +3.5A
Photometric Repeatability ±0.001A at 1A measured at 1.0A at 546 nm
Spectral Bandwidth 5 nm
Stray Light <0.05%T at 340 nm and 400 nm
Wavelength Data Interval 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm
Wavelength Range 325 nm – 1100 nm
Wavelength Repeatability < ±0.2 nm
Wavelength Scan Speed Automatic – up to 1800 nm/min
Weight (Metric) 7.5 kg
Unit Size Each

========================================================================================

Click Here : Thermo Scientific GENESYS 40/50 UV/Vis Spectrophotometer Catalog

Catalog Number
GENESYS 50 UV-Vis Spectrophotometer
840-298000
Optical Design Dual Beam
Spectral Bandwidth 2 nm
Wavelength Range 190 nm – 1100 nm
Detector Type Dual Silicon Photodiodes
Display 7-inch color touchscreen, fixed, high definition, 800 × 1280 pixels
Photometric Accuracy
Instrument
±0.002A at 0.5A     ±0.004A at 1.0A    ±0.008A at 2.0A
Printer Snap-on printer available
Wavelength Accuracy ±0.5 nm
Baseline Flatness ±0.002A
Compartments # Accessible from top, front or side Able to accommodate cells up to 100mm cells
# Available accessory for test tubes up to 25 mm diameter and 150 mm height
# Removable, washable sample compartment liner with magnetic placement and hold-down
Connections # Single USB-A supports flash memory devices for method and data storage
Duplex USB-A on side supports connection to a Windows™ computer
running optional remote control software, keyboard, mouse
# Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor,
available Print via USB, Ethernet or Wi-Fi USB adaptor available
Description GENESYS 50 UV-Vis Spectrophotometer
Dimensions (L x W x H) 35.5 x 38.5 x 19.5 cm
Drift (At 500 nm after 1 hour warmup) <0.0005A/Hr
Electrical
Requirements
External AC to DC converter. Voltage and Frequency (Hz)
selected automatically, 100 – 240 Volts, 50 – 60 Hz.
Keypad Touchscreen
Lamp Xenon Flash Lamp (>5 years typical, 3 years guaranteed)
Noise (RMS at 500 nm 60 consecutive measurements)
≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm
Optical Design Dual beam
Photometric Display -3A to +5A
Photometric Range –2A to +3.5A
Photometric Repeatability ±0.001A at 1A measured at 1.0A at 546 nm
Spectral Bandwidth 2 nm
Stray Light < 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2)
Wavelength Data Interval 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm
Wavelength Range 190 nm – 1100 nm
Wavelength Repeatability < ±0.2 nm
Wavelength Scan Speed Slow, medium and fast – up to 1600 nm/min
Weight (Metric) 7.5 kg
Unit Size Each

========================================================================================

Click Here : Thermo Scientific GENESYS 40/50 UV/Vis Spectrophotometer Catalog

Thermo Scientific Genesys UV/Visible Spectrophotometer Series Specification

Description GENESYS 30 GENESYS 40 GENESYS 140 GENESYS 50 GENESYS 150 BioMate 160 GENESYS 180
Optical Design Single Beam Dual Beam Double Beam
Spectral Bandwidth 5 nm 2 nm
Light Source
(Typical Lifetime)
Tungsten-Halogen (>1000 hours) Xenon Flash Lamp (>5 years typical, 3 years guaranteed)
Detector Silicon Photodiode Dual Silicon Photodiodes
Wavelength
Range 325–1100 nm 190–1100 nm
Accuracy ±2 nm ±0.5 nm
Repeatability <±1 nm <±0.2 nm
Scan
Speed
Automatic – up to
1200 nm/min
Automatic – up to 1800 nm/min Slow, medium and fast (up to 1600 nm/min)
Data
Resolution
1 nm 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm 0.1 nm, 0.2 nm, 0.5 nm,
1 nm, 2 nm, 5 nm
Photometric
Range –3A to +3A –3A to +3.5A –2A to +3.5A
Display –3A to +3A, 0 to 200 000 %T,
0 to 9 999 999 C
–3A to +5A
Accuracy ± 0.002A (0 – 0.3A) 0.5 % of
ABS reading (0.301A – 2.5A)
± 0.002A at 0.5A
± 0.004A at 1.0A
± 0.008A at 2.0A
Repeatability1 ± 0.002 A ± 0.001A at 1A
Noise2 ≤ 0.001A at 0A
≤ 0.001A at 1A
≤ 0.002A at 2A
≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm
Drift3 < 0.002A/Hr < 0.0010A/Hr <0.0005A/Hr
Stray Light < 0.1%T at 340 nm and 400 nm < 0.05%T at 340 nm and 400 nm < 1.0 %T 198 nm (KCl) , < 0.05 %T at 220 nm (NaI),
< 0.03 %T at 340 nm (NaNO2)
Baseline Flatness < 0.003A ± 0.005A ± 0.002A
Display 5-inch diagonal, 32-bit color display,
800 × 480 pixels
7-inch color touchscreen,
fixed, high definition,
800 × 1280 pixels
7-inch color touchscreen,
tiltable, high definition,
800 × 1280 pixels
7-inch color touchscreen,
fixed, high definition,
800 × 1280 pixels
7-inch color touchscreen, tiltable,
high definition, 800 × 1280 pixels
Keypad Tactile rubber 23 keys with numeric keypad Touchscreen
Sample
Compartment
• Accessible from top, front or side
• All platforms can accommodate 100 mm cells
• Available accessory for test-tubes up to 25 mm
diameter and 150 mm height
• Removable, washable sample compartment liner
with magnetic placement and hold-down
Accommodates (optional):
• 8-position cell changer
• 4-position cell changer
(long path cells)
• Peltier thermostatted
cell holder (20–60 °C)
• Sipper accessory
• Accessible from top,
front or side
• Able to accommodate
cells up to 100 mm pathlength
• Available accessory for test-tubes
up to 25 mm diameter and
150 mm height
• Removable, washable sample
compartment liner with magnetic
placement and hold-down
Accommodates (optional):
• 8-position cell changer
• 4-position cell changer
(long path cells)
• Peltier thermostatted
cell holder (20–60 °C)
• Sipper accessory
• Fiber optic probe coupler
• 8-position cell changer
(standard) Also
accommodates (optional):
• 4-position cell changer
(long path cells)
• Peltier thermostatted
cell holder (20–60 °C)
• Sipper accessory
• Fiber optic probe coupler
Printer Snap-on printer available
Connectivity • USB-A on front face supports flash memory devices for method and data storage
• USB-B on side supports connection to a Windows computer running optional remote control software; export data to PC via USB
• Single USB-A supports flash memory devices for method and data storage
• Duplex USB-A supports connection to a Windows computer running optional remote control software,         keyboard, mouse
• Export data to network or PC via Ethernet or Wi-Fi
• Print via USB, Ethernet or Wi-Fi
Languages English (Available soon: Spanish, German, French, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai)
Dimensions 35.5 × 38.5 × 19.5 cm (L × W × H)
Weight 7.5 kg
Power Requirements External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz.
Warranty  1 (one) year

 

PT. Mora Anugerah Berkat sudah berpengalaman menyediakan dan mensupply produk alat-alat instrument/analitik dari Thermo Scientific Genesys Spectrophotometer, kami juga menyediakan berbagai aksessoris dan sparepart dari Genesys Spectrophotometry dan mensupport layanan seperti re-training penggunaan spectrophotometer genesys, jasa perawatan (Maintenance), Jasa Perbaikan (Service) dan mensupport (membantu) untuk kalibrasi dan lain – lain jangan ragu menghubungi kami.