SARTORIUS CUBIS MSU ANALYTICAL BALANCE

Combines classic key-operated control with a wide range of performance features

MSU Analytical Balance are part of the Cubis modular equipment series, which incorporates a precisely-machined second generation monolithic weigh cell for increased accuracy and ultra-fast response for quick results with outstanding repeatability. Cubis is the first and only balance to automatically check, perform and document its exact leveling. It also allows customization to meet specific laboratory applications to fulfill the most stringent requirements in addition to the ability to choose the weighing module and draft shield to allow a user to invest in only what is necessary.

  • Tiltable and removable large, high-resolution monochrome graphic display
  • Key operation, positive click action and precise activation of functions
  • Combines classic key-operated control with a wide range of performance features
  • Comes standard with built in USB, 25-pin RS232C and Ethernet communication interfaces as well as integrated SD card reader for data storage and convenient data transfer
  • Q-Guide: Novel, wizard-supported user/task management for easy operation and programming
  • Ensures safety and reliability of results with Advanced Pharma Compliance via User/password management, audit trail function, alert messages and reminder functions.

Specification :

Power supply : 100-240V, -15%+10%, 50-60Hz, 1.0A

Input Voltage : 15 VDC, + 5%

Power Consumption : 7w (max.)

Ambient Temperature : Operation +5°C to + 40°C

Highest Relative Humidity : 80% for temperature up to 31°C, decreasing linearly to 50% relative humidity for 40°C

Safety of Electrical Equipments : According to EN 61010-1:2001: Safety requirements for electrical equipment for measurement, control, and laboratory use; Part 1: General requirements

Defined Immunity to Interference : Suitable for use in industrial areas

Interference Emission : Class B (suitable for use in residential areas and areas that are connected to a low voltage network that also supplies residential buildings)

 

Sartorius Cubis MSU Analytical Balances
Model Weighing Capacity Readability Repeatability ( < + ) Linearity ( < + ) Stabilization Time (S) Min.Sample Weight
Automatic Draft Shield Doors
MSU124S – 100 – DA 120g 0.1mg 0.1mg 0.2mg 1s 0.12g
MSU224S – 100 – DA 220g 0.1mg 0.07mg 0.2mg 1s 0.12g
MSU324P – 100 – DA 80g; 160g; 320g 0.1/0.2/0.5mg 0.1/0.2/0.4mg 0.5mg 1s 0.12g
MSU324S – 100 – DA 320g 0.1mg 0.1mg 0.3mg 1s 0.12g
MSU524S – 100 – DA 520g 0.1mg 0.2mg 0.2mg 2s 20mg
Manual Draft Shield Doors
MSU124S – 100 – DU 120g 0.1mg 0.1mg 0.2mg 1s 0.12g
MSU224S – 100 – DU 220g 0.1mg 0.07mg 0.2mg 1s 0.12g
MSU324P – 100 – DU 80g; 160g; 320g 0.1/0.2/0.5mg 0.1/0.2/0.4mg 0.5mg 1s 0.12g
MSU324S – 100 – DU 320g 0.1mg 0.1mg 0.2mg 1s 0.12g
MSU524P – 100 – DU 120g; 240g; 520g 0.1/0.2/0.5mg 0.1/0.2/0.5mg 0.2mg 2s 20mg
MSU524S – 100 – DU 520g 0.1mg 0.2mg 0.2mg 2s 20mg