Radioisotope Identification Device (RIID) – FLIR 440

The FLIR identiFINDER R440 is a lightweight, sourceless radioisotope identification device (RIID) that delivers sensitive detection and fast results for routine survey or secondary screening response missions. The 2×2 NaI (sodium iodide) detector responds to radiological threats from farther away, behind heavier shielding, and with better resolution than similarly-sized RIIDs. The extended energy range provides neutron indication. Its light weight makes single-handed operation easy on extended operations, while the IP67-rated enclosure is built to survive. The bold, easy-to-read interface with 360° EasyFinder™ mode expedites decision-making to keep personnel and the community safe

Radioisotope Identification Device (RIID) – FLIR 440

SMALLEST, LIGHTEST RIID WITH 2X2 NaI DETECTOR
Accurate identification and faster time to alarm
3.5 times more sensitive with 10% better resolution than comparatively sized RIIDs
High dose rate range provides stability and accuracy even in high dose rate environments
Two models: gamma only (with neutron indication); gamma and neutron detection and measurement
Sourceless stabilization improves data collection, reducing false positives

 

RUGGED, IP67-RATED ENCLOSURE
Built to survive fast-paced, rigorous missions
Protected from total dust ingress and water immersion (rain, splashing and accidental submersion) up to 1 meter in depth for up to 30 minutes
ANSI N42.42 and ANSI N42.34 compliant
Drop-tested up to 1 meter
Completely enclosed crystal provides enhanced ruggedization

 

STATE-OF-THE-ART USER FEATURES
Clear results and enhanced communications keep responders and the community safe
360° EasyFinder mode collects and interprets data and then pinpoints the exact location of source for user
Built-in wireless communications
Built for interagency standardization – common user interface provides familiarity for users of any identiFINDER product

Radioisotope Identification Device (RIID) – FLIR 440

 

FLIR identiFINDER R440 Specifications

General

Technology

Radioisotope identification device (RIID)

Gamma – NaI(Tl)

51 x 51 mm (2.0 x 2.0″)

Gamma/Neutron NaIL

51 x 51 mm (2.0 x 2.0″)

Energy Range (Gamma)

10 keV to 10 MeV

Gamma Sensitivity

1850 cps/μSv/h

(Cs-137, NaI)

Gamma Spectrum Length

1024 channels

Dose Rate Range

10 n Sv/h – 10 m Sv/h

(Cs-137, NaI)

(1 μrem/h – 1 rem/h) ± 30%

Dose Rate Range ID

10 n Sv/h – 250 m μSv/h

Mode (Cs-137, NaI)

(1 μrem/h – 25 μrem/h)

Overload Dose

10 n Sv/h – 500 m μSv/h

Rate Range (Cs-137, NaI)

(1 μrem/h – 50 μrem/h)

Stabilisation

Sourceless gain stabilisation

(patents pending).

Linearisation

Real-time linearisation of gamma energy.

Typical Resolution

≤ 7% FWHM at 662 keV

with NaI detector at 20°C

Sampling and Analysis

Sample Introduction

Absorption of EM gamma (NaI) or

gamma and neutron emissions (NaIL).

Threats

Detects neutron or gamma radiation

emitted from natural occurrences in the

environment, special nuclear material,

industrial, or medical material.

Nuclide Identification

According to ANSI N42.34

Library Categories

SNM, IND, MED, NORM.

Time to Alarm

From a few seconds to minutes.

System Interface

Display and Alerts

Transflective colour LCD / 3″

(2.72″ x 1.61″) Colour TFT Display,

Resolution: 800 x 480 pixels.

Communication

USB 2.0, USB OTG; Bluetooth® Class 2.0

≤10 m range (removable);

WiFi 802.11 g/n

Data Storage

32 GB internal memory

Training Requirements

<10 mins for operator; 1 day for advanced user.

GPS (removable)

12-channel SiRF III receiver

Software

On-board webserver software

Power

Input Voltage

100 – 24- V AC (wall adapter and USB cable supplied.

Battery Specifications

Supplied: 2 x rechargeable Li-Ion smartpacks and 1 x 4 x AA pack;

≤ 6 h runtime with one Li-Ion smartpack, ≤ 12 h with both Li-Ion;

runtime of ≤ 4 h with AA battery pack (Li-Ion);

Optional rechargeable NiMH ion smartpack with ≤ 5 h runtime;

recharge ≤ 4 h when using AC; recharge > 4 h when using USB; run

times specified are obtained with a mix of Dose Rate, Finder, and ID

operating mode.

Cold Start Time

<2 mins from cold start.

Environmental

Operating Temperature

-20 to 50°C (4 to 122°F)

(Ambient)

Operating Humidity

10 to 80%

Storage Temperature

-10 to 35°C (14 to 95°F)

Physical Features

Dimensions (W x L x H))

10.2 x 26.9 x 9.4 cm

Weight

≤1.5 kg

Enclosure and Protection

Aluminium housing protection rating IP67 according to IEC 60529.

NB : PT. Mora Anugerah Berkat sudah terdaftar dalam E-Katalog

Kami juga menyediakan berbagai brand / merk internasional dari USA, Eropa dan China, produk internasional yang kami supply/tawarkan ; Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.

Radioisotope Identification Device (RIID) – FLIR 440

 

PT. Mora Anugerah Berkat (M.A.B)
Click Here : FLIR identiFINDER R440 Brochure
Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang – Provinsi Banten
Phone : 021 7345.7064
Mobile/HP : 0812.8140.0749 / 0812.8770.5470
Chat : Whats App, Line, WeChat, Telegram
Website : www.moraanugerah.idwww.moraanugerah.com
Email : info@moraanugerah.id – marketing@moraanugerah.com – marketing_div@moraanugerah.com