Portable Combution

 

Portable Combution 

 

Hand-held, 4-gas Combustion & Emissions Analyzer for CO, O2, NO, NO2, & SO2

Bacharach’s PCA 400 combustion & emissions analyzer offers everything technicians need to commission, tune, maintain and certify any boiler.

  • Versatile analyzer for many commercial and industrial applications with up to 4 gas sensors (O2, CO, NO, NO2 and SO2)

  • Optional active sample conditioner provides superior accuracy for low NOx and SOx applications

  • Real-time PC software allows technicians to view and save live data for easy compliance reporting

  • Combustion App allows users to remotely operate the analyzer and create custom reports with comments which can be sent via email (available for Android & iOS)

  • Long life O2 sensor with 5 year warranty reduces maintenance costs and downtime

  • Automatic dilution mode and sensor protection helps technicians protect the analyzer in harsh environments, extending sensor life

  • Dual Bluetooth® and IrDA printer allows technicians to reproduce combustion and emissions reports in the field

  • Quick and easy (replacement) B-Smart® Sensor replacement in the field reduces downtime and doesn’t require calibration gas

  • Click Here : BACHARACH PCA 400 Combustion & Emissions Analyzer

 

Description

Bacharach’s PCA® 400 combustion & emissions analyzer offers everything you and your technicians need to commission, tune, maintain and certify any boiler. It is perfect for spot-checking and tuning your engines with the high-range CO sensor and available sample conditioner. Whether it’s boiler combustion or emissions testing of your natural gas, stationary genset or mobile fleet vehicles, monitoring your emissions is fast, easy and accurate.

Users have the option to save measured data in the unit as discreet tests, or stream it live via Bluetooth® communications to a PC or other smart hand-held device for compliance reporting. Reports are easily and quickly generated to satisfy compliance requirements. Interchangeable power options (rechargeable Li-Ion, ‘AA’ alkalines or line power) ensure the unit is always ready for use. Probes and hoses come in a variety of lengths and materials to satisfy a wide range of applications, including NOx, SO2 and other requirements. Automatic sensor protection not only guards the sensors from damage, but doubles their measurement range under high load conditions for increased flexibility.

*Note: The PCA® 400 calculates CO2value based upon other measured values during the combustion process. It does not measure CO2 directly.

Portable Combution 

Product Specifications

Sensors:

Up to 4

Measuring

Range:

O2: 0 to 20.9%

CO-H2 compensated: 0 to 10,000 ppm

CO (high): 0 to 40,000 ppm

NO: 0 to 3,000 ppm

NO2: 0 to 500 ppm

SO2: 0 to 5,000 ppm

Stack Temperature:

-4 to 2192°F (-20 to 1200°C)

Draft / Differential Pressure:

± 72 inH2O (± 179 mB)

User Interface:

Color touch panel LCD

Display Size:

4.3 in. (10.9 cm)

Power:

Rechargable Li-Ion battery pack,

4 × Alkaline Batteries, Wall Adapter (5V USB)

Run Time:

12 to 14 Hours (Rechargeable Li-Ion Battery Pack)

Warm-Up Time:

60 seconds

Digital Communications:

USB 2.0 (micro-B), IrDA, Bluetooth®

Ambient Temperature:

32 to 113°F (0 to 45°C)

Humidity:

15 to 90% RH (non-condensing)

Altitude:

1 ATM ± 10%

Product Dimensions (L×W×H):

10″ × 3.8″ × 2.5″ (25.4 × 9.7 × 6.4 cm)

Product Weight:

1.5 lb. (0.68 kg) w/ Li-Ion battery pack

Fuel Equations:

Natural gas, coal, oil 2/4/6, propane, wood/biofuel, kerosene, bagasse, digester gas, B5, pellets, KOKS, LEG, LPG, butane, wood chips

Sample

Flow Rate:

0.6 to 0.7 L/min (standard),

1.0 L/min (high flow mode)

Approvals:

CE, EN 50379-1, EN 50379-2

Internal Memory:

500 Records

Warranty:

Instrument: 2 Years, O2 Sensor: 5 Years

Printer:

IrDA + Bluetooth Printer (Optional)

Country of Origin:

United States

 

Common Configurations

Description

Part Number

PCA 400 w/ O2, CO, 12 in. probe with 7.5 ft. standard tubing and standard case

2410-1110

PCA 400 w/ O2, CO, 12 in. probe with 7.5 ft. standard tubing and standard case and Bluetooth® printer

2410-1112

PCA 400 w/ O2, CO, NO, 12 in. probe with 7.5 ft. standard tubing and standard case

2411-1110

PCA 400 w/ O2, CO, NO, 12 in. probe with 7.5 ft. standard tubing and standard case and Bluetooth® printer

2411-1112

PCA 400 w/ O2, CO, NO, NO2, 12 in. probe with 7.5 ft. Viton™ tubing and standard case

2412-1310

PCA 400 w/ O2, CO, NO, NO2, 12 in. probe with 7.5 ft. Viton™ tubing, standard case and Bluetooth® printer

2412-1312

PCA 400 w/ O2, CO, NO, SO2, 12 in. probe with 7.5 ft. Viton™ tubing and standard case

2413-1310

PCA 400 w/ O2, CO, NO, SO2, 12 in. probe with 7.5 ft. Viton™ tubing, standard case and Bluetooth® printer

2413-1312

PCA 400 w/ O2, CO, SO2, 12 in. probe with 7.5 ft. Viton™ tubing and standard case

2414-1310

PCA 400 w/ O2, COHIGH, 7.5 ft. standard tubing and standard case

2420-1110

PCA 400 w/ O2, CO, SO2, 12 in. probe with 7.5 ft. Viton™ tubing, standard case and Bluetooth® printer

2414-1312

PCA 400 w/ O2, COHIGH, 12 in. probe with 7.5 ft. standard tubing, standard case and Bluetooth® printer

2420-1112

 

Accessories and Parts

Bacharach’s Combustion app, the companion app to Bacharach combustion analyzers, provides technicians the ability to generate and send customizable combustion reports from their smartphone / tablet.

Features of the Combustion App:

  • QR Code Scanner (Intech & Insight Plus only): Scan a QR code generated on the analyzer display screen for immediate creation and transmission of combustion reports

  • Wireless Bluetooth Connectivity (PCA 400 only): View real-time combustion data from your device, simultaneously save data to the mobile app and to the analyzer memory, and remotely start / stop the analyzer sampling pump

  • Set up customer profiles with facility and equipment information

  • Save and view records of test data

  • Generate reports in PDF, CSV, or XML format using saved records

  • Send or share a report file as an email attachment or to a cloud storage service

  • Include up to 10 data records in a single report

  • Insert comments for each data record in a report

  • Click Here : BACHARACH PCA 400 Combustion & Emissions Analyzer

 

Portable Combution 

 

Description

Part Number

North American sample conditioner kit. Includes sample conditioner, replacement filters (3 pk.) and North American outlet power supply.

0024-8558

Bluetooth® + IrDA Printer Kit

0024-1680

IrDA Printer Kit

0024-1400

Printer Paper (5 rolls)

0024-1310

True Spot® Smoke Kit

0021-7006

Thermocouple (10 ft., for combustion air temperature)

0104-1797

Thermocouple (1 in., for ambient air temperature)

0104-1798

Calibration Kit (includes on-demand regulator, fittings and tubing)

0024-7059

Small Pressure Plug Kit

0024-1747

Differential Pressure and Temperature Kit

0024-8242

Differential Temperature Kit

0024-8258

Differential Pressure Kit

0024-8259

High temperature particulate filter

0024-3150

Click Here : BACHARACH PCA 400 Combustion & Emissions Analyzer

 

Calibration Gas

Description

Part Number

500 ppm CO in air

0024-0492

1,000 / 1,000 ppm CO/H2 in N2

0024-0794

100 ppm NO in N2

0024-1697

100 ppm NO2 in N2

0024-1157

100 ppm SO2 in N2

0024-1158

Small Pressure Plug Kit

0024-1747

Differential Pressure and Temperature Kit

0024-8242

Differential Temperature Kit

0024-8258

Differential Pressure Kit

0024-8259

High temperature particulate filter

0024-3150

 

Portable Combution

 

Probe and Hose Assemblies

Description

Part Number

Probe handle assembly with 12 in. probe tube

0024-3231

Probe handle assembly with 24 in. probe tube

0024-3232

Probe handle assembly with 36 in. probe tube

0024-3233

Hose assembly, standard tubing, 7.5 ft.

0024-3234

Extended hose assembly, standard tubing, 15 ft.

0024-3235

Hose assembly, Viton™, 7.5 ft.

0024-3236

Extended hose assembly, Viton™, 15 ft.

0024-3237

 

Click Here : BACHARACH PCA 400 Combustion & Emissions Analyzer

 

Replacement Sensors

Description

Part Number

CO sensor (0 – 10,000 ppm) uncalibrated

0024-1660

CO sensor (0 – 10,000 ppm) pre-calibrated

0024-1687

Sensor Exchange Program (3 years, 1 Sensor every 9 months)

CO sensor (0 – 10,000 ppm)

0024-3080

CO High sensor (0 – 40,000 ppm) uncalibrated

0024-0997

CO High sensor (0 – 40,000 ppm) pre-calibrated

0024-1542

Sensor Exchange Program (3 years, 1 Sensor every 9 months)

CO High sensor (0 – 40,000 ppm)

0024-3062

NO sensor (0 – 3,000 ppm) uncalibrated

0024-0881

NO sensor (0 – 3,000 ppm) pre-ncalibrated

0024-1691

Sensor Exchange Program (3 years, 1 Sensor every 9 months)

NO sensor (0 – 3,000 ppm)

0024-3084

NO2 sensor (0 – 500 ppm) uncalibrated

0024-1027

NO2 sensor (0 – 500 ppm) pre-calibrated

0024-1544

Sensor Exchange Program (3 years, 1 Sensor every 9 months)

NO2 sensor (0 – 500 ppm)

0024-3064

SO2 sensor (0 – 5,000 ppm) uncalibrated

0024-0998

SO2 sensor (0 – 5,000 ppm) pre-calibrated

0024-1543

SO2 sensor (0 – 5,000 ppm)

0024-3065

O2 sensor (5 to 7 Years) (0 – 20.9%)

0024-1652

 

SUPPORTED GASES:

============================================================================

 

 

Portable Combution