METTLER TOLEDO™ Excellence Plus XP Microbalances

Standard Equipment

  • SmartSens, Sensor for hands free operation
  • SmartGrid, grid weighing pan for fast and stable results
  • SmartScreen, color display for safe and user-friendly operation
  • Seven different applications with user guidance (incl. density determination, statistical analysis, formulation and differential weighing)
  • ErgoClip Basket small, or ErgoClip Basket micro (with models XP56/ • Individual reports can be defined with up to 4 IDs XP26). Holder for tare containers for ergonomic weighing
  •  MinWeigh warns if the minimum weight is not reached (Minimum weight determined on site by service technician)
  • User Management for granting access rights
  • Level Control warns when the balance is not levelled
  • BalanceCheck, prompts automatically for validation with external weights
  • ProFACT, fully-automatic temperature and/or time-controlled internal adjustment and linearisation
  • Built-in RS232 interface and two auxiliary outlets
  • Slot for second interface (7 options)
  • Height-adjustable inner draft shield
  • Motor-driven draft shield doors
  • Completely dismountable draft shield for easy cleaning
  • Terminal can be positioned separately from the balance
  • Protective cover for the terminal
  • Production certificate

METTLER TOLEDO™ Excellence Plus XP Microbalances

Click Here : XP Series High Performance and Analytical Balance

XP Analytical Balances
Technical Data (Limit Values) XP105DR XP205 XP205DR XP204 XP504 XP504DR
Maximum Capacity 120 g 220 g 220 g 220 g 520 g 520 g
Maximum Capacity, Fine Range 31 g 81 g 101 g
Readability 0.1 mg 0.01 mg 0.1 mg 0.1 mg 0.1 mg 1 mg
Readability, Fine Range 0.01 mg 0.01 mg 0.1 mg
Repeatability
– (at nominal load) 0.06 mg (100 g) 0.03 mg (200 g) 0.06 mg (200 g) 0.07 mg (200 g) 0.12 mg (500 g) 0.6 mg (500 g)
– (at low load) 0.05 mg (10 g) 0.015 mg (10 g) 0.05 mg (10 g) 0.05 mg (10 g) 0.1 mg (10 g) 0.5 mg (10 g)
– (at low load), fine range 0.015 mg (10 g) 0.015 mg (10 g) 0.1 mg (10 g)
Linearity 0.15 mg 0.1 mg 0.15 mg 0.2 mg 0.4 mg 0.5 mg
Excentric Load Deviation (test load) 1) 0.2 mg (50 g) 0.2 mg (100 g) 0.25 mg (100 g) 0.25 mg (100 g) 0.4 mg (200 g) 0.5 mg (200 g)
Sensitivity Offset 4×10–6•Rnt 2×10–6•Rnt 2.5×10–6•Rnt 3×10–6•Rnt 3×10–6•Rnt 4×10–6•Rnt
Sensitivity Temperature Drift2) 1×10–6/°C•Rnt 1×10-–6/°C•Rnt 1×10–6/°C•Rnt 1×10–6/°C•Rnt 1×10–6/°C•Rnt 1×10–6/°C•Rnt
Sensitivity Stability 3) 1×10–6/a•Rnt 1×10–6/a•Rnt 1×10–6/a•Rnt 1×10–6/a•Rnt 1×10–6/a•Rnt 1×10–6/a•Rnt
Interface Update Rate 23/s 23/s 23/s 23/s 23/s 23/s

Click Here : XP Series High Performance and Analytical Balance

Typical values for calculating the measurement uncertainty
Repeatability* (sd) 0.04 mg+1×10-7 Rgr 0.007 mg +6×10-8 Rgr 0.04 mg+5×10-8 Rgr 0.04 mg+5×10-8 Rgr 0.04 mg+6×10-8 Rgr 0.4 mg+2×10–7•Rgr
Repeatability*,
fine range (sd)
0.007 mg +1.5×10-7 Rgr 0.007 mg +1.2×10-7 Rgr 0.04 mg+2.0×10–7•Rgr
Differential linearity
deviation (sd)
√2.5×10–11g Rnt √5×10–12g Rnt √1,2×10–11g Rnt √2×10–11g Rnt √5×10–11g Rnt √8×10–11g Rnt
Differential eccentric
load deviation (sd)
1×10-6 Rnt 5×10-7 Rnt 5×10-7 Rnt 6×10-7 Rnt 5×10-7 Rnt 5×10–7•Rnt
Sensitivity offset (sd)2) 1×10-6 Rnt 5×10–7•Rnt 8×10-7 Rnt 1×10-6 Rnt 6×10-7 Rnt 8×10–7•Rnt
Minimum weight
(according to USP)
21 mg+4.5×10-4 Rgr 21 mg+1.8×10-4 Rgr 21 mg+3.6×10-4 Rgr 120 mg+1.5×10-4 Rgr 120 mg+1.8×10-4 Rgr 120 mg+6×10–4•Rgr
Minimum weight *
(U=1%, 2 sd)
1.4 mg+3.0×10-5 Rgr 1.4 mg+1.2×10-5 Rgr 1.4 mg+2.4×10-5 Rgr 8 mg+1×10-5 Rgr 8 mg+1.2×10-5 Rgr 8 mg+4×10–5•Rgr
Settling time 1.5s 2.5s 1.5s 1.5s 1.5s 1.5s
Settling time, fine range 4s 6s 4s 4s 4s 3.5s

METTLER TOLEDO™ Excellence Plus XP Microbalances

XP Micro Balances
Technical Data (Limit Values) XP26 XP26DR XP56 XP56DR
Maximum Capacity 22 g 22 g 52 g 52 g
Maximum Capacity, Fine Range 5.1 g 11 g
Readability 0.001 mg 0.01 mg 0.001 mg 0.01 mg
Readability, Fine Range 0.002 mg 0.002 mg
Repeatability
– (at nominal load) 0.0025 mg (20 g) 0.008 mg (20 g) 0.006 mg (50 g) 0.014 mg (50 g)
– (at low load) 0.0015 mg (1 g) 0.005 mg (1 g) 0.0015 mg (1 g) 0.006 mg (1 g)
– (at low load), fine range 0.002 mg (1 g) 0.002 mg (1 g)
Linearity 0.006 mg 0.01 mg 0.02 mg 0.03 mg
Excentric Load Deviation (test load) 1) 0.02 mg (10 g) 0.025 mg (10 g) 0.03 mg (20 g) 0.035 mg (20 g)
Sensitivity Offset 4×10-6 Rnt 5×10-6 Rnt 2.5×10–6•Rnt 3×10–6•Rnt
Sensitivity Temperature Drift2) 1×10–6/°C•Rnt 1×10–6/°C•Rnt 1×10–6/°C•Rnt 1×10–6/°C•Rnt
Sensitivity Stability 3) 1×10–6/a•Rnt 1×10–6/a•Rnt 1×10–6/a•Rnt 1×10–6/a•Rnt
Interface Update Rate 23/s 23/s 23/s 23/s

Click Here : XP Series High Performance and Analytical Balance

Typical values for calculating the measurement uncertainty
Repeatability* (sd) 0.0007 mg+4×10-8 Rgr 0.004 mg+5×10-8 Rgr 0.0007 mg+6×10-8 Rgr 0.004 mg+6×10-8 Rgr
Repeatability*,
fine range (sd)
0.0012 mg+1×10-7 Rgr 0.0012 mg+1×10-7 Rgr
Differential linearity
deviation (sd)
√1.2×10-13g Rnt √3×10-13g Rnt √5×10-13g Rnt √1.2×10-12g Rnt
Differential eccentric
load deviation (sd)
3×10-7 Rnt 4×10-7 Rnt 3×10-7 Rnt 4×10-7 Rn
Sensitivity offset (sd)2) 1×10-6 Rnt 1.2×10-6 Rnt 6×10-7 Rnt 8×10-7 Rnt
Minimum weight
(according to USP)
2.1 mg+1.2×10-4 Rgr 3.6 mg+3×10-4 Rgr 2.1 mg+1.8×10-4 Rgr 3.6 mg+3×10-4 Rgr
Minimum weight *
(U=1%, 2 sd)
0.14 mg+8×10-6 Rgr 0.24 mg+2×10-5 Rgr 0.14 mg+1.2×10-5 Rgr 0.24 mg+2×10-5 Rgr
Settling time 3.5s 2.5s 3.5s 2.5s
Settling time, fine range 3.5s 3.5s

METTLER TOLEDO™ Excellence Plus XP Microbalances