Measuring range max. |
40000 J |
Measuring mode dynamic 25°C |
yes |
Measuring modeisoperibol 25°C |
yes |
Measuring time dynamic approx. |
8 min |
Measuring time isoperibol approx. |
17 min |
Reproducibility dynamic (1g benzoic acid NBS39i) |
0.1 %RSD |
Reproducibility isoperibol (1g benzoic acid NBS39i) |
0.1 %RSD |
Working temperature max. |
25 °C |
Temperature measurement resolution |
0.0001 K |
Interface printer |
Centronix |
Interface PC |
RS232 |
Decomposition Vessel C 5010 |
yes |
Works according to DIN 51900 |
yes |
Works according to DIN EN ISO 1716 |
yes |
Works according to DIN EN ISO 18125 |
yes |
Works according to DIN EN 15400 |
yes |
Works according to DIN CEN TS 14918 |
yes |
Works according to DIN CEN/TS 16023 |
yes |
Works according to DIN SPEC 19524 |
yes |
Works according to ASTM D240 |
yes |
Works according to ASTM D4809 |
yes |
Works according to ASTM D5468 |
yes |
Works according to ASTM D5865 |
yes |
Works according to ISO 1928 |
yes |
Works according to GOST Certified |
yes |
Dimensions (W x H x D) |
400 x 400 x 400 mm |
Weight |
28.912 kg |
Permissible ambient temperature |
20 – 25 °C |
Permissible relative humidity |
80 % |
Protection class according to DIN EN 60529 |
IP 20 |
RS 232 interface |
yes |
Voltage |
100 – 240 V |
Frequency |
50/60 Hz |
Power input |
120 W |
IKA Calorimeters C 3000 Isoperibol |
|
Specification |
|
Technical Data |
|
Measuring range max. |
40000 J |
Measuring mode dynamic 22°C |
yes |
Measuring mode isoperibol 22°C |
yes |
Measuring mode dynamic 30°C |
yes |
Measuring mode isoperibol 30°C |
yes |
Measurements/h dynamic |
6 |
Measurements/h isoperibol |
4 |
Reproducibility dynamic (1g benzoic acid NBS39i) |
0.15 %RSD |
Reproducibility isoperibol (1g benzoic acid NBS39i) |
0.05 %RSD |
Touchscreen |
yes |
Working temperature |
22 – 30 °C |
Temperature measurement resolution |
0.0001 K |
Cooling medium temperature |
12 – 27 °C |
Cooling medium permissible operating pressure |
1.5 bar |
Cooling medium |
tap water |
Type of cooling |
flow |
Chiller |
RC 2 basic |
Flow rate |
60 – 70 l/h |
Rec. flow rate at 18°C |
60 l/h |
Oxygen operating pressure max. |
40 bar |
Interface scale |
RS232 |
Interface printer |
USB |
Interface PC |
RS232 |
Interface ext. keyboard |
yes |
Oxygen filling |
yes |
Decomposition vessel C 6010 |
yes |
Decomposition vessel C 6012 |
yes |
Analysis according to ASTM D240 |
yes |
Analysis according to ASTM D4809 |
yes |
Analysis according to ASTM D5865 |
yes |
Analysis according to ISO 1928 |
yes |
Analysis according to GB T213 |
yes |
Dimensions (W x H x D) |
500 x 425 x 450 mm |
Weight |
29 kg |
Permissible ambient temperature |
20 – 30 °C |
Permissible relative humidity |
80 % |
Protection class according to DIN EN 60529 |
IP 20 |
RS 232 interface |
yes |
USB interface |
yes |
Voltage |
100 – 120 V |
Frequency |
50/60 Hz |
Power input |
1700 W |
IKA Calorimeters C 6000 |
|
Specification |
|
Technical Data |
|
Measuring range max. |
40000 J |
Measuring mode adiabatic 22°C |
yes |
Measuring mode dynamic 22°C |
yes |
Measuring mode isoperibol 22°C |
yes |
Measuring mode adiabatic 25°C |
yes |
Measuring mode dynamic 25°C |
yes |
Measuring mode isoperibol 25°C |
yes |
Measuring mode adiabatic 30°C |
yes |
Measuring mode dynamic 30°C |
yes |
Measuring mode isoperibol 30°C |
yes |
Measurements/h adiabatic |
5 |
Measurements/h dynamic |
6 |
Measurements/h isoperibol |
4 |
Reproducibility adiabatic (1g benzoic acid NBS39i) |
0.05 %RSD |
Reproducibility dynamic (1g benzoic acid NBS39i) |
0.15 %RSD |
Reproducibility isoperibol (1g benzoic acid NBS39i) |
0.05 %RSD |
Touchscreen |
yes |
Working temperature |
22 – 30 °C |
Temperature measurement resolution |
0.0001 K |
Cooling medium temperature |
12 – 27 °C |
Cooling medium permissible operating pressure |
1.5 bar |
Cooling medium |
tap water |
Type of cooling |
flow |
Chiller |
RC 2 basic |
Flow rate |
60 – 70 l/h |
Rec. flow rate at 18°C |
60 l/h |
Oxygen operating pressure max. |
40 bar |
Interface scale |
RS232 |
Interface printer |
USB |
Interface PC |
RS232 |
Interface test rack |
yes |
Interface ext. keyboard |
yes |
Oxygen filling |
yes |
Degasification |
yes |
Decomposition detection |
yes |
Decomposition vessel C 6010 |
yes |
Analysis according to DIN 51900 |
yes |
Analysis according to ASTM D240 |
yes |
Analysis according to ASTM D4809 |
yes |
Analysis according to ASTM D5865 |
yes |
Analysis according to ISO 1928 |
yes |
Analysis according to GB T213 |
yes |
Works according to DIN 51900 |
yes |
Works according to DIN EN ISO 1716 |
yes |
Works according to DIN EN ISO 9831 |
yes |
Works according to DIN EN ISO 18125 |
yes |
Works according to DIN EN 15170 |
yes |
Works according to DIN EN 15400 |
yes |
Works according to DIN CEN TS 14918 |
yes |
Works according to DIN CEN/TS 16023 |
yes |
Works according to DIN SPEC 19524 |
yes |
Works according to ASTM D240 |
yes |
Works according to ASTM D4809 |
yes |
Works according to ASTM D5468 |
yes |
Works according to ASTM D5865 |
yes |
Works according to ISO 1928 |
yes |
Works according to GB T213 |
yes |
Works according to GOST Certified |
yes |
Dimensions (W x H x D) |
500 x 425 x 450 mm |
Weight |
73.26 kg |
Permissible ambient temperature |
20 – 30 °C |
Permissible relative humidity |
80 % |
Protection class according to DIN EN 60529 |
IP 20 |
RS 232 interface |
yes |
USB interface |
yes |
Voltage |
220 – 240 V |
Frequency |
50/60 Hz |
Power input |
1700 W |