IKA Bomb Calorimeter (C1 AND C2 200 TYPE)
Calorimeters
IKA oxygen bomb calorimeters are the market leaders when it comes to determining the calorific values of liquid and solid samples. The selection of IKA oxygen bomb calorimeters is optimally geared towards various different demands. Calorimeter portfolio includes: C1, C 200 and C 6000 calorimeters.
C 1, the smallest fully automated calorimeter that works with a static-jacket.
The entry level model C 200, the most cost-effective calorimeter, is easily operated manually. With low purchase cost, the C 200 is an ideal calorimeter for learning and teaching purposes. However, it can be upgraded to achieve fully automated water-handling or by operating it through a PC with the calorimeter software Calwin C 6040.
The C 6000 series offers a high level of automation along with being easy to handle. The C 6000 global standards is for example the only calorimeter of its kind worldwide, combining all three 3 classic methods into one device at 3 different starting temperatures. The C 6000 global standards enables users to determine adiabatic, isoperibol, and dynamic (reduced time) calorific values.
Functionality, safety, and longevity are the main goals in the development of IKA oxygen bomb calorimeters.
Berikut Ini adalah link dari catalog produk dari calorimeter IKA sebagai berikut :
Click Here : IKA Bomb Calorimeter Catalogue
IKA Calorimeters C 200 |
|
Specification |
|
Technical Data |
|
Measuring range max. |
40000 J |
Measuring mode dynamic 25°C |
yes |
Measuring mode isoperibol 25°C |
yes |
Measuring time dynamic approx. |
8 min |
Measuring time isoperibol approx. |
17 min |
Reproducibility dynamic (1g benzoic acid NBS39i) |
0.1 %RSD |
Reproducibility isoperibol (1g benzoic acid NBS39i) |
0.1 %RSD |
Working temperature max. |
25 °C |
Temperature measurement resolution |
0.0001 K |
Interface printer |
Centronix |
Interface PC |
RS232 |
Decomposition Vessel C 5010 |
yes |
Works according to DIN 51900 |
yes |
Works according to DIN EN ISO 1716 |
yes |
Works according to DIN EN ISO 18125 |
yes |
Works according to DIN EN 15400 |
yes |
Works according to DIN CEN TS 14918 |
yes |
Works according to DIN CEN/TS 16023 |
yes |
Works according to DIN SPEC 19524 |
yes |
Works according to ASTM D240 |
yes |
Works according to ASTM D4809 |
yes |
Works according to ASTM D5468 |
yes |
Works according to ASTM D5865 |
yes |
Works according to ISO 1928 |
yes |
Works according to GOST Certified |
yes |
Dimensions (W x H x D) |
400 x 400 x 400 mm |
Weight |
28.912 kg |
Permissible ambient temperature |
20 – 25 °C |
Permissible relative humidity |
80 % |
Protection class according to DIN EN 60529 |
IP 20 |
RS 232 interface |
yes |
Voltage |
100 – 240 V |
Frequency |
50/60 Hz |
Power input |
120 W |
================================================
IKA Bomb Calorimeter (C1 AND C2 200 TYPE)
================================================
IKA Calorimeters C 3000 Isoperibol |
|
Specification |
|
Technical Data |
|
Measuring range max. |
40000 J |
Measuring mode dynamic 22°C |
yes |
Measuring mode isoperibol 22°C |
yes |
Measuring mode dynamic 30°C |
yes |
Measuring mode isoperibol 30°C |
yes |
Measurements/h dynamic |
6 |
Measurements/h isoperibol |
4 |
Reproducibility dynamic (1g benzoic acid NBS39i) |
0.15 %RSD |
Reproducibility isoperibol (1g benzoic acid NBS39i) |
0.05 %RSD |
Touchscreen |
yes |
Working temperature |
22 – 30 °C |
Temperature measurement resolution |
0.0001 K |
Cooling medium temperature |
12 – 27 °C |
Cooling medium permissible operating pressure |
1.5 bar |
Cooling medium |
tap water |
Type of cooling |
flow |
Chiller |
RC 2 basic |
Flow rate |
60 – 70 l/h |
Rec. flow rate at 18°C |
60 l/h |
Oxygen operating pressure max. |
40 bar |
Interface scale |
RS232 |
Interface printer |
USB |
Interface PC |
RS232 |
Interface ext. keyboard |
yes |
Oxygen filling |
yes |
Decomposition vessel C 6010 |
yes |
Decomposition vessel C 6012 |
yes |
Analysis according to ASTM D240 |
yes |
Analysis according to ASTM D4809 |
yes |
Analysis according to ASTM D5865 |
yes |
Analysis according to ISO 1928 |
yes |
Analysis according to GB T213 |
yes |
Dimensions (W x H x D) |
500 x 425 x 450 mm |
Weight |
29 kg |
Permissible ambient temperature |
20 – 30 °C |
Permissible relative humidity |
80 % |
Protection class according to DIN EN 60529 |
IP 20 |
RS 232 interface |
yes |
USB interface |
yes |
Voltage |
100 – 120 V |
Frequency |
50/60 Hz |
Power input |
1700 W |
================================================
IKA Bomb Calorimeter (C1 AND C2 200 TYPE)
================================================
IKA Calorimeters C 6000 |
|
Specification |
|
Technical Data |
|
Measuring range max. |
40000 J |
Measuring mode adiabatic 22°C |
yes |
Measuring mode dynamic 22°C |
yes |
Measuring mode isoperibol 22°C |
yes |
Measuring mode adiabatic 25°C |
yes |
Measuring mode dynamic 25°C |
yes |
Measuring mode isoperibol 25°C |
yes |
Measuring mode adiabatic 30°C |
yes |
Measuring mode dynamic 30°C |
yes |
Measuring mode isoperibol 30°C |
yes |
Measurements/h adiabatic |
5 |
Measurements/h dynamic |
6 |
Measurements/h isoperibol |
4 |
Reproducibility adiabatic (1g benzoic acid NBS39i) |
0.05 %RSD |
Reproducibility dynamic (1g benzoic acid NBS39i) |
0.15 %RSD |
Reproducibility isoperibol (1g benzoic acid NBS39i) |
0.05 %RSD |
Touchscreen |
yes |
Working temperature |
22 – 30 °C |
Temperature measurement resolution |
0.0001 K |
Cooling medium temperature |
12 – 27 °C |
Cooling medium permissible operating pressure |
1.5 bar |
Cooling medium |
tap water |
Type of cooling |
flow |
Chiller |
RC 2 basic |
Flow rate |
60 – 70 l/h |
Rec. flow rate at 18°C |
60 l/h |
Oxygen operating pressure max. |
40 bar |
Interface scale |
RS232 |
Interface printer |
USB |
Interface PC |
RS232 |
Interface test rack |
yes |
Interface ext. keyboard |
yes |
Oxygen filling |
yes |
Degasification |
yes |
Decomposition detection |
yes |
Decomposition vessel C 6010 |
yes |
Analysis according to DIN 51900 |
yes |
Analysis according to ASTM D240 |
yes |
Analysis according to ASTM D4809 |
yes |
Analysis according to ASTM D5865 |
yes |
Analysis according to ISO 1928 |
yes |
Analysis according to GB T213 |
yes |
Works according to DIN 51900 |
yes |
Works according to DIN EN ISO 1716 |
yes |
Works according to DIN EN ISO 9831 |
yes |
Works according to DIN EN ISO 18125 |
yes |
Works according to DIN EN 15170 |
yes |
Works according to DIN EN 15400 |
yes |
Works according to DIN CEN TS 14918 |
yes |
Works according to DIN CEN/TS 16023 |
yes |
Works according to DIN SPEC 19524 |
yes |
Works according to ASTM D240 |
yes |
Works according to ASTM D4809 |
yes |
Works according to ASTM D5468 |
yes |
Works according to ASTM D5865 |
yes |
Works according to ISO 1928 |
yes |
Works according to GB T213 |
yes |
Works according to GOST Certified |
yes |
Dimensions (W x H x D) |
500 x 425 x 450 mm |
Weight |
73.26 kg |
Permissible ambient temperature |
20 – 30 °C |
Permissible relative humidity |
80 % |
Protection class according to DIN EN 60529 |
IP 20 |
RS 232 interface |
yes |
USB interface |
yes |
Voltage |
220 – 240 V |
Frequency |
50/60 Hz |
Power input |
1700 W |
IKA Bomb Calorimeter (C1 AND C2 200 TYPE)
Berikut Ini adalah link dari catalog produk dari calorimeter IKA sebagai berikut :
-
PT.Mora Anugerah Berkat
-
Click Here : IKA Bomb Calorimeter Catalogue
-
Click Here : PT.Mora Anugerah Berkat sudah terdaftar di E-Katalog LKPP
-
Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan, Kota Tangerang – Provinsi Banten
-
Phone : 021 7345.7064
-
Mobile : 0812.8140.0749 / 0812.8770.5470
-
Chat : Whats App, Line, WeChat, Telegram
-
Website : www.moraanugerah.id – www.moraanugerah.com
-
Email : info@moraanugerah.com – info@moraanugerah.id – marketing_div@moraanugerah.com