Item
|
Specifications
|
General
Parameters
|
Power Supply
|
AC220V, 50/60 Hz (Standard)
1320VA ; 110V 60Hz (Optional)
|
Size (L*W*H)
|
950*645*(1250-11450) mm
|
Maximum heater output power (220VAC)
|
Air chamber heater: 330W;
|
Water tank heater: 155W
|
Auxillary network power output
|
AC 220V / 50Hz, Both maximum permissible currents are 220V 1.5A
|
Heater indication
|
0-100%, 10% increasing amount
|
Temperature control mode
|
Bed temperature mode ; The skin temperature mode
|
Bed temperature control
|
25.0 – 37.0°C;
|
temperature range
|
37.1 – 39.0°C (Span Mode)
|
Skin temperature sensor temperature display range
|
5.0 – 65.0°C
|
Heating time
|
< 50min
|
Temperature variability
|
< 0.5°C
|
Temperature uniformity
(mattress in horizontal position)
|
< 0.8°C
|
Temperature uniformity
(mattress in tilted position)
|
< 1.0°C
|
Difference between average incubator temperature and control temperature
|
< 1.5°C
|
Skin temperature sensor accuracy
|
=+0.3°C’
|
Humidity
Control
|
The running time of the tank after it is filled with distilled water
|
Humidity below 70%RH, at least 24h
|
Water tank capacity
|
1500ml
|
Humidity display range
|
0%RH – 99%RH
|
Humidity control range
|
CAH%RH – 90%RH(1% per adjustment)
|
Humidity control accuracy
|
1
|
Oxygen
Concentration
Control
|
Oxygen concentration
display range
|
0% – 99%
|
Oxygen concentration display resolution
|
1%
|
Oxygen concentration control accuracy
|
=+5% oxygen volume concentration’
|
Oxygen concentration setting range
|
21% – 60% (1% per adjustment)
|
Oxygen sensor
service life
|
The maximum use time is 10000h at
100 % oxygen concentration
|
Transport
Storage
|
Temperature
|
-2°C – +55°C
|
Atmospheric pressure range
|
500hPa – 1060hPa
|
Relative humidity
|
< 93% RH
|
Packing Size /
Gross Weight
|
Base packing size: 1200*800*870mm 50kg
|
Body packing size: 1100*710*855mm 60kg
|
The
Work
Environment
|
Relative humidity
|
30%RH – 75%RH
|
The environment temperature
|
=+20°C – + 30°C’
|
Pressure range
|
700hPa – 1060hPa
|
Service altitude
|
< 2000m
|
Over voltage category
|
II
|
Pollution levels
|
2
|
Ambient air velocity
|
< 0.3m/s
|
Other
Indicator
|
Environmental noise in
incubator baby compartment
|
No more than 55dB(A) at stable temperature
|
Carbon dioxide concentration in the infant compartment
|
A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL/min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0.5% after stabilization
|
The velocity of air flow over a baby’s mattress
|
< 0.35m/s
|
General
Alarm
|
Power off alarm, Fan alarm, sensor alarm, Deviation alarm, Over temperature alarm, Water tank placement error alarm, Water shortage alarm
|
The
System
Alarm
|
Mcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, Analog-to-digital conversion chip 2544 fault alarm, Analog-to-digital conversion chip 2548 fault alarm, Over temperature alarm, Temperature heating system fault, Humidity heating system fault
|