ECOM J2KN Pro TECH Analyzer Calibration
ECOM J2KN Pro TECH Analyzer Calibration
PT. Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan / mensupply peralatan pengujian lingkungan khususnya untuk industri, pertambangan atau instansi pemerintah di bidang lingkungan seperti ECOM J2KN Pro TECH Analyzer Calibration, kami juga menyediakan peralatan yang sudah teruji dan sesuai dengan Standard,kami juga menyediakan berbagai brand/merk internasional dari USA, Eropa dan China,produk internasional yang kami supply/tawarkan seperti : ECOM USA, Bacharach, Seitron, Testo dan lain – lain.
ECOM-J2KNpro SERIES
The J2KNpro Series represents the ultimate work horse for industrial gas analysis. It’s performance and accuracy is unsurpassed in the field of portable emissions and combustion analysis.
Offers wireless connectivity, multiple reporting tools, and can be used for CTM-030 & CTM-034, tools, and can be used for CTM-030 & CTM-034, SCAQMD 1146.1, MSAPR testing.
ECOM J2KN Pro TECH Analyzer Calibration
ECOM-J2KNpro STANDARD FEATURES : |
|
UP TO SIX (6) SENSORS |
DATA LOGGING WITH MEMORY CARD |
USB INTERFACE |
HEATED SENSOR BLOCK |
INDUSTRIAL PELTIER COOLER & PUMP |
CO OVER RANGE PROTECTION |
DIGITAL FLOW METER |
AIR LEAK DETECTION |
Click Here : ECOM J2KN Pro TECH Brochure
ECOM-J2KNpro OPTIONAL FEATURES : |
|
UP TO THREE (3) NDIR SENSORS (CO2, CO, & HYDROCARBON) |
EXTERNAL ANTENNA FOR INCREASED WIRELESS RANGE |
DUAL RANGE CO SENSORS |
BLUETOOTH OR WI-FI |
HEATED SAMPLE LINE POWER CONNECTION |
DAS AND REPORTING SOFTWARE |
FRESH AIR PURGE |
STACK FLOW VELOCITY |
ECOM J2KN Pro TECH Analyzer Calibration
SPECIFICATIONS : |
ECOM-J2KNpro SERIES |
|||
Measurements |
Range |
Accuracy |
Resolution |
Sensor type |
Oxygen (O2) |
0-20% vol |
± 0.2% vol |
0.1% vol |
Electrochemical |
Carbon Monoxide (CO) |
0-10,000 ppm |
± 2% Measured* |
1.0 ppm |
Electrochemical |
Carbon Monoxide (high) |
0-63,000 ppm |
± 2% Measured* |
5.0 ppm |
Electrochemical |
Nitric Oxide (NO) |
0-5000 ppm |
± 5% Measured* |
1.0 ppm |
Electrochemical |
Nitric Oxide (low) |
0-500 ppm |
± 5% Measured* |
0.1 ppm |
Electrochemical |
Nitrogen Dioxide (NO2 ) |
0-1000 ppm |
± 5% Measured* |
1.0 ppm |
Electrochemical |
Nitrogen Dioxide (low) |
0-100 ppm |
± 5% Measured* |
0.1 ppm |
Electrochemical |
Sulfur Dioxide (SO2) |
0-5000 ppm |
± 5% Measured* |
1.0 ppm |
Electrochemical |
Combustibles (Cx Hy ) |
0-4.00% vol |
0.01% vol |
Pellistor |
|
Methane (CH4 ) |
0-3.00% vol |
± 3% Measured* |
0.001% vol |
Infrared bench |
Carbon Dioxide (CO2 ) |
0-20% |
± 5% Measured* |
0.1% vol |
Infrared bench |
Carbon Monoxide (CO) |
1000-63,000 ppm |
± 5% Measured* |
10 ppm |
Infrared bench |
Propane |
0-2000 ppm |
± 5% Measured* |
1.0 ppm |
Infrared bench |
Hydrogen Sulfide (H2 S) |
0-1000 ppm |
± 5% Measured* |
1.0 ppm |
Electrochemical |
Draft / Pressure |
±40” H2O |
± 2% Measured* |
0.004” H2O |
DMS |
Gas Temperature |
32-1832° F** |
± 0.5% |
||
Ambient Temperature |
40-122° F |
± 1° F |
||
O2 Correction |
0-20% O2 |
Calculated |
||
Carbon dioxide |
0-CO2 max of fuel |
Calculated |
||
Smoke Scale |
0-9 |
|||
Kami juga menyediakan Jasa Perbaikan (SERVICE),Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.
ECOM J2KN Pro TECH Analyzer Calibration
Untuk informasi,pertanyaan dan pemesanan silahkan hubungi kami di :
-
PT. Mora Anugerah Berkat (M.A.B)
-
Click Here : ECOM J2KN Pro TECH Brochure
-
Click Here : BACHARACH PCA 400 Brochure
-
Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang – Provinsi Banten
-
Phone : 021 7345.7064 / 7366.0160
-
Mobile: 0812.8140.0749 / 0812.8770.5470
-
Chat : Whats App, Line, WeChat, Telegram
-
Website : www.moraanugerah.id – www.moraanugerah.com
-
Email : info@moraanugerah.com – info@moraanugerah.id – marketing_div@moraanugerah.com