NIC - Mercury Analyzer [RA-5A]
NIC - Mercury Analyzer [RA-5A]
The RA-5A delivers ultra-high sensitivity and excellent precision while only requiring 5ml os sample. The RA-5A is also environmentally-friendly thorughits direct purge design that reduces reagent consumption and waste production by over 80% versus comparable model without any need for compressed gases
RA-5A has achieved the highest level sensivity and accuracy with new innovatory-crafted detector optics
Sample |
N |
Average |
C.V |
0.05μg/L |
5 |
0.052μg/L |
2.2 % |
0.10µg/L |
5 |
0.101μg/L |
1.70% |
Click Here : Mercury Analyzer RA-5A Brochure
NIC - Mercury Analyzer [RA-5A]
Nippon Instruments Corporation |
||
Specifications |
Mercury Analyzer RA – 5A |
|
DataProcessingSoftware |
Measurement Principle |
Non-dispersive double beam cold vaporatomatic absorption spectrometry [Patent Pending] |
Measurement Method |
Reducing Vaporrization with open air-supply (Peak height measuring and integration measuring salectable) |
|
Light Source |
Low pressure mercury discharge lamp |
|
Wave Length |
253.7 nm |
|
Detector |
semicondutor sensor (w/254nm bandpass filter) |
|
Detection Limit |
0,0025ng/5ml (0.5ppt) |
|
Maximum Range |
2.000ng/5ml (400 ppb) |
|
Carrier Gas Required |
No0 Compressed purified gas Required |
|
Measure Flow Rate |
Adjustable (0.1 - 0.9 L/min) (just operet with ambient air) |
|
Measuring Time |
30sec - 999sec |
|
Dehumidifier |
Peltier device |
|
Mercury Removal |
Removal by activated carbon |
|
MercuryDetectionSection |
OS |
Windows 10 Pro |
Comunication |
USB |
|
Display |
Peak Wave shape,calibration curve,measuring time and measuring result |
|
Data |
Selectable from 6 formula (3 liniear and 3rd order fits), Correlation |
|
Processing |
coefficient is automatically calculated Static calculation : Mean Value, standard deviation Coefficient of variation |
|
Software |
(All value are automatically calculated), self check function |
|
|
|
Measuring conditions,Calibration Curve,Measured values,Statical Calculations Peak wave shape and Measuring time |
|
Quality Control |
Check Standard, Avoid abnormally high mercury |
|
Instalation Dimension |
248W x 253D x 180H (mm) |
|
Weight |
4,7 (Kg) |
|
Instalation Enviroment |
10°C - 35°C, < 10 - 80% RH (Non condensing enviroment is allowed) |
|
Power Supply |
AC, single phase, 100 - 240V 50/60 Hz, 150VA (AC Adaptor Included) |
|
Kami juga menyediakan Jasa Perbaikan (SERVICE), Jasa Perawatan (Maintenace) dan support untuk KALIBRASI / AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.
NIC - Mercury Analyzer [RA-5A]
-
PT. Mora Anugerah Berkat (M.A.B)
-
Click Here : Mercury Analyzer RA-5A Brochure
-
Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan,Kota Tangerang - Provinsi Banten
-
Phone : 021 7345.7064
-
Mobile : 0812.8140.0749 / 0812.8770.5470
-
Chat : Whats App,Line,WeChat,Telegram
-
Website : www.moraanugerah.id - www.moraanugerah.com
-
Email : info@moraanugerah.com - marketing@moraanugerah.com - marketing_div@moraanugerah.com