Blog General Laboratory Equipment
Mercury Analyzer [NIC] MA-3 Solo
5 Juli 2023
•
1x dilihat
Nippon Instrument Corporation
Mercury Analyzer
Mercury Analyzer | MA-3 Solo
Jual Mercury Analyzer | MA-3 Solo
Harga Mercury Analyzer | MA-3 Solo
Portable Mercury Analyzer Price
Jual Portable Mercury Analyzer
Mercury Analyzer MA-3 Solo Manual
Mercury Analyzer Principle
Mercury Analyzer Manufacturer
distributor nippon instrument corporation
portable mercury analyzer
nippon mercury analyzer
ma-3 solo mercury analyzer
thermal decomposition
atomic absorption
ma 300
jual ma-3 solo mercury analyzer
ps analytical mercury analyzer
portable and compact direct mercury analyzer
thermal vaporization mercury analyzer ma-3 solo
harga ma-3 solo mercury analyzer
nic ma-3 solo
jual nic ma-3 solo
harga nic ma-3 solo
nic ma-3 solo specification
ma-3 solo direct mercury analyzer
jual ma-3 solo direct mercury analyzer
harga ma-3 solo direct mercury analyzer
ma-3 solo - hg-nic
mercury analyzer indonesia
distributor mercury analyzer indonesia
cold vapor mercury analyzer
mercury analyzer perkin elmer
mercury analyzer ma-3000
nippon ma-3000
pe-100 mercury analyzer
harga portable mercury analyzer
distributor nippon mercury analyzer
lumex mercury analyzer
direct mercury analyzer
tekran mercury analyzer
automated mercury analyzer
mercury analyzer hitachi
mercury instruments gmbh mercury analyzer
mercury vapor analyzer
hg 400 mercury analyzer
Mercury Analyzer [NIC] MA-3 Solo
Mercury Analyzer [NIC] MA-3 Solo
Mercury Analyzer MA-3 SOLO
Affordable,High Performance Direct Mercury Analysis
-
USEPA 7473
-
ASTM D 6722-01
-
ASTM D7623-10
-
UOP 1009-15
-
JIS K0102
MA-3 Solo Key Feature and Benefits
AFFORDABLE ROBUST DESIGN WITH A WIDE MEASUREMENT RANGE
Engineered for affordability, with easy-to-use manual boat loading and a sturdy “quick twist” load lock, the rugged MA-3 Solo is simple to operate and delivers a wide measurement range of 0 to 10,000 ng with quick analysis times ranging from 5 to 12 minutes.
INEXPENSIVE OPERATION – NO GASES OR CONSUMABLES REQUIRED
MA-3 Solo was designed to be as simple to use as possible. Unlike other systems that require purifi ed oxygen gas, purifi ed air is used as the combustion and carrier gas. This design concept makes the instrument perfect for fi eld portable operation or for use in mobile laboratories. The ceramic sample boats are easily cleaned for reuse. No gas requirement and reusable boats keep operating costs low.
ADVANCED OPTICS FOR SUPERIOR SENSITIVITY AND STABILITY
Employing a high-quality thermally stabilized Hg-discharge lamp that emits a very strong, stable line emission at 253.7 nm eliminates the need for any intensity-robbing optical fi ltering of the source. Two rugged semiconductor detectors provide the quantitative and reference measurements, ensuring a long lifetime of trouble-free operation. Other systems use inexpensive 50% transmittance mirrors to redirect the light source, but this reduces the intensity, lowering sensitivity. Instead, MA-3 Solo uses high quality optical gratings to redirect the full intensity through the sample cell and to the reference detector, for superior sensitivity and stability.
Specifications
|
Thermal Decomposition Mercury Analyzer MA-3 Solo
|
Measuring Object
|
Solid Sample ; Liquid Samples ; Gaseous Sample
|
Analysis Method
|
Thermal decomposition-gold amalgam collection
cold atomic absorption spectrometry
|
Measurement Principle
|
Non-dispersion double-beam cold atomic absorption spectrometry
|
Light Source
|
Low-pressure mercury discharge lamp
|
Detector
|
Semiconductor detector (with 254 nm bandpass filter)
|
Detection Limit Precision
|
Detection limit: 0.01 ng ; Precision : RSD 3% (0.1 ng or greater) *3
|
Measuring Range
|
0 to 10,000 ng
|
Analysis Time
|
5 to 12 minutes
|
Flow Rate at Measurement
|
0.2 L/min
|
Exhaust Gas Treatment
|
Activated carbon fi lter for removing mercury
|
Sample Heating Temperature
|
Up to 850°C
|
Heating Control
|
3 Step setting (temperature time arbitrary setting possible)
|
Carrier Gas
|
Self-purifi ed ambient air
|
Sample Bottle
|
Dedicated ceramic boat (Capacity: 1.5 mL)
|
Size / Weight
|
403 W × 252 D ×300 H (mm), 13 kg (~28 lbs)
|
Power Source
|
AC100-240 V, 50/60 Hz, 1.1 KVA
|
Useage Enviroment
|
Temperature: 15 to 35°C ; Humidity : 10 to 80% RH (no dew condensation)
|
Standard Accesssories
|
Sample boat (10) ; boat stands ; boat tongs ; L-cysteine
|
OS
|
Windows 10 Pro
|
Comunnication
|
USB
|
Display
(Japanese / English)
|
Peak waveform ; calibration curve graph ;
measurement process ; measurement result ; equipment status
|
Data Processing
|
Calibration curve (linear formula ×3 types; cubic formula × 3 types) ; unit setup ; concentration computation ; baseline correction ; statistical calculation (mean value; standard deviation; CV%)
|
Precision Control
|
Equipment check ; evaluation of calibration curve ; blank check; recovery calculation
|
Printing
|
Memo ; calibration formula/graph ; measured value table ;
statistical calculation ; peak waveform measurement date and time ;
result of equipment check
|
PT. Mora Anugerah Berkat (M. A. B) adalah perusahaan yang sudah berpengalaman dalam menyediakan / mensupply peralatan enviromental equipment (alat uji lingkungan) seperti Mercury Analyzer [NIC] MA-3 Solo , kami juga menyediakan berbagai brand / merk internasional dari USA, Eropa dan China, produk internasional yang kami supply / tawarkan seperti : Nippon Instruments Corporation , Lumex Instrument , Pall Instrument dan masih banyak lagi, Untuk informasi, pertanyaan dan pemesanan silahkan hubungi kami di :
Mercury Analyzer [NIC] MA-3 Solo
-
PT. Mora Anugerah Berkat [M.A.B]
-
-
-
-
Alamat : Jl.Taman Asri Blok M No.36 Kel.Cipadu Kec.Larangan, Kota Tangerang - Provinsi Banten
-
Phone : 021 7345.7064 / 7366.0160
-
Mobile : 0812.8140.0749 / 0812.8770.5470
-
Chat : Whats App, Line, WeChat, Telegram
-
-
Email : info@moraanugerah.com - info@moraanugerah.id - marketing_div@moraanugerah.com