| Distance Measurement
|
|
|
|
| Typical Measuring Tolerance[1]
|
± 2.0 mm[3] |
± 1.0 mm[3] |
± 1.0 mm[3] |
| Maximum Measuring Tolerance[2]
|
± 3.0 mm[3] |
± 2.0 mm[3] |
± 2.0 mm[3] |
| Range at Leica target plate GZM26
|
50 m/165 ft |
80 m/260 ft |
100 m/330 ft |
| Typical Range[1]
|
40 m/130 ft |
80 m/260 ft |
80 m/260 ft |
| Range at Unfavorable condition[4]
|
35 m/115 ft |
60 m/195 ft |
60 m/195 ft |
| Smallest Unit Displayed
|
1 mm /1/16 in |
1 mm /1/32 in |
1 mm /1/32 in |
| Power Range Technology™
|
no |
yes |
yes |
| laser point at distances
|
6/30/60 mm (10/50/100m) ; 0.23/1.18/2.36 in (32.8/164/330) |
6/30/60 mm (10/50/100m) ; 0.23/1.18/2.36in (32.8/164/330) |
6/30/60 mm (10/50/100m) ; 0.23/1.18/2.36in (32.8/164/330) |
| Tilt Measurement
|
|
|
|
| Measuring Tolerance to laser beam[5]
|
no |
no |
± 0.2° |
| Measuring tolerance to housing[5]
|
no |
no |
± 0.2° |
| Range
|
no |
no |
360° |
| General
|
|
|
|
| Laser class
|
II |
II |
II |
| Laser type
|
635 nm, <1 mW |
635 nm, <1 mW |
635 nm, <1 mW |
| Protection class
|
IP40 |
IP54 |
IP54 |
| Automatic laser off
|
After 90 seconds |
After 90 seconds |
After 90 seconds |
| Automatic power off
|
After 180 seconds |
After 180 seconds |
After 180 seconds |
| Battery life
(2 x AAA) 1.5V NEDA 24A/IEC LR03 |
up to 3,000 measurements |
up to 5,000 measurements |
up to 5,000 measurements |
| Size (HxWxD) |
116 mm x 53mm x 33mm ;
(4.56in x 2.08in x 1.29in) |
127 mm x 56mm x 33mm ;
(5in x 2.20in x 1.29in) |
127mm x 56mm x 33mm ;
(5in x 2.20in x 1.29in) |
| Weight
(with batteries) |
113 g (3.98 oz) |
153 g (5.39 oz) |
158 g (5.57 oz) |
| Temperature Range : Storage Operation
|
-25 °C to +70°C (-13 °F to +158 °F)
0 °C to +40 °C (32 °F to +104 °F) |
-25°C to +70°C (-13 °F to +158 °F)
-10 °C to +50 °C (14 °F to + 122 °F) |
-25 °C to +70°C (-13 °F to +158 °F)
-10 °C to +50 °C (14 °F to +122 °F) |
| Calibration cycle
|
Not applicable |
Not applicable |
tilt and compass |
| Maximum altitude
|
3000 m |
3000 m |
3000 m |
| Maximum relative humidity |
85 % at 20 °F to 120 °F;
(-7 °C to 50 °C) |
85 % at 20 °F to 120 °F ;
(-7 °C to 50 °C) |
85 % at 20 °F to 120 °F ;
(-7 °C to 50 °C) |
| Safety |
CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01,IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)
|
CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01,IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II) |
CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01,IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II) |
| EMC |
61326-1:2006
|
61326-1:2006 |
61326-1:2006 |