BIOLAB Climatic Chamber
|
Series 1400
|
Climatic Chamber BCCL-1401
-
Capacity: 50 L
-
Temperature Range: RT+10-85°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: ±1.0°C
-
Humidity control range: 80-95%RH
|
Climatic Chamber BCCL-1402
-
Capacity: 100 L
-
Temperature Range: RT+10-85°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: ±1.0°C
-
Humidity control range: 80-95%RH
|
Climatic Chamber BCCL-1403
-
Capacity: 250 L
-
Temperature Range: RT+10-85°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: ±1.0°C
-
Humidity control range: 80-95%RH
|
Climatic Chamber BCCL-1404
-
Capacity: 50 L
-
Temperature Range: 10-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1405
-
Capacity: 50 L
-
Temperature Range: 20-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1406
-
Capacity: 50 L
-
Temperature Range: 40-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1407
-
Capacity: 100 L
-
Temperature Range: 10-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability:
-
High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1408
-
Capacity: 100 L
-
Temperature Range: 20-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability:
-
High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1409
-
Capacity: 100 L
-
Temperature Range: 40-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability:
-
High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1410
-
Capacity: 250 L
-
Temperature Range: 10-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1411
-
Capacity: 250 L
-
Temperature Range: 20-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1412
-
Capacity: 250 L
-
Temperature Range: 40-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1413
-
Capacity: 500 L
-
Temperature Range: 10-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1414
-
Capacity: 500 L
-
Temperature Range: 20-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1415
-
Capacity: 500 L
-
Temperature Range: 40-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1416
-
Capacity: 800 L
-
Temperature Range: 10-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1417
-
Capacity: 800 L
-
Temperature Range: 20-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1418
-
Capacity: 1000 L
-
Temperature Range: 10-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp: ±1°C
-
Humidity control range: 35-95%RH
|
Climatic Chamber BCCL-1419
-
Capacity: 1000 L
-
Temperature Range: 20-100°C
-
Temperature Accuracy: 0.1°C
-
Temperature Stability: High temp: ±0.5°C Low temp ±1°C
-
Humidity control range: 35-95%RH
|
|
|