Introduction :

Infant Radiant Warmer is one of the important equipment used in medical institutions. It is mainly used for constant temperature cultivation, temperature resuscitation, oxygen delivery, rescue, hospitalization and observation of sick infants and premature infants. It is used in hospitals, confinement centers, neonatology, etc.

 

Automatic Infant Radiant Warmer

 

Features :

 

Automatic Infant Radiant Warmer

 

Technical Parameters :

Infant Radiant Warmer

Item

Specifications

General

Parameters

Power Supply

AC 220V, 50/60 Hz (Standard)
1320 VA; 110V 60Hz (Optional)

Size (L*W*H)

950 * 645 * (1250 – 11450) mm

Maximum Heater
Output Power (220VAC)

Air chamber heater: 330W;
Water tank heater: 155W

Auxillary network
power output

AC 220V / 50Hz, Both maximum permissible
currents are 220V 1.5A

Heater indication

0-100%, 10% increasing amount

Temperature control mode

Bed temperature mode ; The skin temperature mode

Bed temperature control

25.0 – 37.0°C;

temperature range

37.1 – 39.0°C (Span Mode)

Skin temperature sensor
temperature display range

5.0 – 65.0°C

Heating time

< 50min

Temperature variability

< 0.5°C

Temperature uniformity
(mattress in horizontal position)

< 0.8°C

Temperature uniformity
(mattress in tilted position)

< 1.0°C

Difference between average
incubator temperature and control temperature

< 1.5°C

Skin temperature sensor accuracy

+0.3°C

Humidity

Control

The running time of the tank
after it is filled with distilled water

Humidity below 70 % RH,
at least 24h

Water tank capacity

1500ml

Humidity display range

0% RH – 99% RH

Humidity control range

CAH % RH – 90 % RH
(1% per adjustment)

Humidity control accuracy

1

Oxygen

Concentration

Control

Oxygen concentration display range

0% – 99%

Oxygen concentration display resolution

1%

Oxygen concentration control accuracy

+5% oxygen volume concentration

Oxygen concentration setting range

21% – 60% (1% per adjustment)

Oxygen sensor
service life

The maximum use time is 10000 h at
100 % oxygen concentration

Transport

Storage

Temperature

-2°C – +55°C

Atmospheric pressure range

500hPa – 1060hPa

Relative humidity

< 93% RH

Packing size / Gross weight

Base packing size : 1200 * 800 * 870 mm; 50kg

Body packing size: 1100 * 710 * 855 mm; 60kg

The Work

Environmental

Relative humidity

30%RH – 75%RH

The environment temperature

“+20°C – + 30°C

Pressure range

700hPa – 1060hPa

Service altitude

< 2000m

Over voltage category

II

Pollution levels

2

Ambient air velocity

< 0.3m/s

General Alarm

  • Environmental noise in incubator baby compartment

  • Carbon dioxide concentration in the infant compartment

  • The velocity of air flow over a baby’s mattress

  • Power off alarm, Fan alarm, sensor alarm, Deviation alarm, Over temperature alarm, Water tank placement error alarm, Water shortage alarm

  • No more than 55dB(A) at stable

  • temperature

  • A mixture of 4% carbon dioxide and air was fed into an 8 mm diameter tube in the vertical direction from the mat to the top of the box at 750 mL / min to a point 10 cm above the mattress center and 10 cm above the center.

  • The concentration was less than 0.5% after stabilization < 0.35m/s

  • Power off alarm, Fan alarm, Sensor alarm, Deviation alarm, Over temperature alarm, Water tank placement error alarm, Water shortage alarm

The System

Alarm

MCU1 and MCU2 communication error alarm, MCU2 and MCU3 communication error alarm,Analog-to-digital conversion chip 2544 fault alarm, Analog-to-digital conversion chip 2548 fault alarm, Over temperature alarm, Temperature heating system fault,Humidity heating system fault

 

Configuration :

Model

BK-3201 (I)

BK-3201 (II)

Temp.Control

Bed/Skin temperature

Bed/Skin temperature

Display

LCD

LCD

Bed Temp. Control Range

25°C – 39°C

25°C – 39°C

Skin Temp. Control Range

34°C – 38°C

/

Humidity Control Range

CAH% – 99%RH

CAH% – 99%RH

Oxygen Control Range

21% – 99%

/

Cabinet

Yes

Yes

 

 

PT.Mora Anugerah Berkat adalah perusahaan yang sudah berpengalaman dalam menyediakan/mensupply peralatan laboratorium untuk Medical Laboratory Equipment & Hospital Suupplier salah satunya adalah Infant Radiant Warmer, kami juga menyediakan peralatan baik lokal maupun custom (khusus) yang sudah teruji dan sesuai dengan standard kesehatan,kami juga menyediakan berbagai brand/merk internasional dari USA,Eropa,China dan lokal,etc.

 

Kami juga menyediakan Jasa Perbaikan (SERVICE),Jasa Perawatan (Maintenace) dan support untuk KALIBRASI/AKSESSORIES SPAREPART jangan ragu untuk menghubungi kami marketing dan sales kami siap membantu menjawab segala kebutuhan anda.

 

Automatic Infant Radiant Warmer