Infant Radiant Warmer |
||
Item |
Specifications |
|
GeneralParameters |
Power Supply |
AC 220V, 50/60 Hz (Standard)
|
Size (L*W*H) |
950 * 645 * (1250 – 11450) mm |
|
Maximum Heater
|
Air chamber heater: 330W;
|
|
Auxillary network
|
AC 220V / 50Hz, Both maximum permissible
|
|
Heater indication |
0-100%, 10% increasing amount |
|
Temperature control mode |
Bed temperature mode ; The skin temperature mode |
|
Bed temperature control |
25.0 – 37.0°C; |
|
temperature range |
37.1 – 39.0°C (Span Mode) |
|
Skin temperature sensor
|
5.0 – 65.0°C |
|
Heating time |
< 50min |
|
Temperature variability |
< 0.5°C |
|
Temperature uniformity
|
< 0.8°C |
|
Temperature uniformity
|
< 1.0°C |
|
Difference between average
|
< 1.5°C |
|
Skin temperature sensor accuracy |
+0.3°C |
|
HumidityControl |
The running time of the tank
|
Humidity below 70 % RH,
|
Water tank capacity |
1500ml |
|
Humidity display range |
0% RH – 99% RH |
|
Humidity control range |
CAH % RH – 90 % RH
|
|
Humidity control accuracy |
1 |
|
OxygenConcentrationControl |
Oxygen concentration display range |
0% – 99% |
Oxygen concentration display resolution |
1% |
|
Oxygen concentration control accuracy |
+5% oxygen volume concentration |
|
Oxygen concentration setting range |
21% – 60% (1% per adjustment) |
|
Oxygen sensor
|
The maximum use time is 10000 h at
|
|
TransportStorage |
Temperature |
-2°C – +55°C |
Atmospheric pressure range |
500hPa – 1060hPa |
|
Relative humidity |
< 93% RH |
|
Packing size / Gross weight |
Base packing size : 1200 * 800 * 870 mm; 50kg |
|
Body packing size: 1100 * 710 * 855 mm; 60kg |
||
The WorkEnvironmental |
Relative humidity |
30%RH – 75%RH |
The environment temperature |
“+20°C – + 30°C |
|
Pressure range |
700hPa – 1060hPa |
|
Service altitude |
< 2000m |
|
Over voltage category |
II |
|
Pollution levels |
2 |
|
Ambient air velocity |
< 0.3m/s |
|
General Alarm |
|
|
The SystemAlarm |
MCU1 and MCU2 communication error alarm, MCU2 and MCU3 communication error alarm,Analog-to-digital conversion chip 2544 fault alarm, Analog-to-digital conversion chip 2548 fault alarm, Over temperature alarm, Temperature heating system fault,Humidity heating system fault |
Model |
BK-3201 (I) |
BK-3201 (II) |
Temp.Control |
Bed/Skin temperature |
Bed/Skin temperature |
Display |
LCD |
LCD |
Bed Temp. Control Range |
25°C – 39°C |
25°C – 39°C |
Skin Temp. Control Range |
34°C – 38°C |
/ |
Humidity Control Range |
CAH% – 99%RH |
CAH% – 99%RH |
Oxygen Control Range |
21% – 99% |
/ |
Cabinet |
Yes |
Yes |